EN
7.3.4
Other important display fields
Reset maximum values dialog
Select measurements
Acoustic alarm
Backlighting
52
The Reset maximum values dialog allows the following stored
maximum values to be reset to 0:
• Maximum daily power
• Maximum daily yield
• Absolute maximum power
Selection of the measurements to be shown in the status
display. The following measurements can be selected:
• Output power: output power of the inverter
• Reactive power: current reactive power in var
• Act. day yield: daily yield from 0:00 until now.
• PV voltage: the voltage supplied by the solar modules
• PV current: the current supplied by the solar modules
• Grid voltage L1
, L2, L3
1)
• Grid current L1, L2, L3: the current fed into the mains
grid
• Grid frequency
• Internal temp.: the internal temperature of the inverter
• Power reduction (Derating): cause of the power reduc-
tion
• Day max. power: the maximum power supplied in the
current day
2)
• Abs. max. power: the maximum power ever fed into the
grid
2)
• Day max. yield: the maximum daily yield achieved
• Operating hours: the operating hours during which the
device has been connected to the grid (including night-
time hours)
• Total yield: yield since commissioning
• CO
saving: CO
savings achieved since commissioning
2
2
Measurement is always displayed (cannot be switched off)
1)
Can be reset to 0 via Settings/Reset max. values
2)
An acoustic alarm sounds (approx. 4.5 kHz) when an event
message is displayed.
• 2 tones: warning
• 3 tones: error
• off
• automatic: switches on for 30 seconds when a button is
pushed
• grid feed:
Not feeding: switches on for 30 seconds when a but-
–
ton is pushed; then switches off
Feeding: switches on for 30 seconds when a button is
–
pushed; then dims