3. Alarm setting for temperature
4. Alarm setting for relative humidity
5. Defining a restricted temperature range
6. Resetting the day counter / Reset to factory setting
7. Useful hints/Incubation table
8. Cleaning and care of the Easy Breeder
9. Problems and solutions
10. Safety instructions and technical data
11. Declaration of conformity
12. Warranty
1. Starting up:
1.1 First connect the power cable to the Easy Breeder and then plug the connector into the mains socket.
1.2 Now press the
ON / OFF - key
1.3 An alarm signal sounds. You can clear alarms at any time by pressing the
1.4 Open the Easy Breeder fill the 7 water channels using the included bottle. These are located underneath the deposition grid. Each channel has a
capacity for 1 full bottle (approx. 200 ml) of water.
1.5 Set the temperature to the desired value. Different temperatures are required for different reptiles (see incubation table.
2. Setting the temperature:
2.1 Press the
menu - key
control panel once.
2.2 Press the
up arrow -
or
2.3 Press the
menu - key
again to complete this process.
The temperature indicator in the control panel always shows the current temperature. The
activated. The setting range is 20.0 – 39.5° C. Adjustable in 0.1° C increments.
3. Alarm setting for temperature: The factory setting for the temperature alarm is programmed at 1° C above or below the defined desired
temperature. When this value is exceeded an alarm signal sounded. If you wish to change this setting, proceed as follows:
3.1 Setting the low temperature alarm (AL):
3.1.1 Hold the
menu - key
3.1.2 Press the
up arrow -
3.1.3 Press the
menu - key
3.1.4 Use the
arrow keys
3.1.5 Press the
menu - key
3.2 Setting the high temperature alarm (AH):
3.2.1 Hold the
menu - key
3.2.2 Press the
up arrow -
3.2.3 Press the
menu - key
3.2.4 Use the
arrow keys
3.2.5 Press the
menu - key
4. Alarm setting for relative humidity (AS): The factory setting for the
value, an alarm signal sounded. If you wish to change this setting, proceed as follows:
4.1 Hold the
menu - key
for approx. 3 seconds.
4.2 Press the
up arrow -
or
4.3 Press the
menu - key
again to confirm.
4.4 Use the
arrow keys
to set the desired alarm limit. The setting range is 1 – 99 %
4.5 Press the
menu - key
again to complete the process.
5. Defining a restricted temperature range: This function prevents that the temperature accidentally exceeds or drops below the defined
desired temperature. The factory setting has no defined limit. If you wish to change this setting, proceed as follows:
5.1 Setting the upper temperature limit (HS):
5.1.1 Hold the
menu - key
5.1.2 Press the
up arrow -
5.1.3 Press the
menu - key
5.1.4 Use the
arrow keys
5.1.5 Press the
menu - key
5.2 Setting the lower temperature limit (LS):
5.2.1 Hold the
menu - key
6
Dohse Aquaristik GmbH & Co. KG · Otto-Hahn-Str. 9 · 53501 Gelsdorf · Germany · www.dohse-terraristik.com
to switch on the Easy Breeder
down arrow - key
to set the desired temperature.
for approx. 3 seconds.
or
down arrow - key
until the display reads (AL).
again to confirm.
to set the lower alarm limit. The setting range is 0.0 – 15.0° C. Can be set in 0.1° C steps.
again to complete the process.
for approx. 3 seconds.
down arrow - key
until the display shows (AH).
or
again to confirm.
to set the lower alarm limit. The setting range is 0.0 – 15.0° C. Can be set in 0.1° C steps.
again to complete the process.
down arrow - key
until the display shows (AS).
for approx. 3 seconds.
down arrow - key
until the display shows (HS).
or
again to confirm.
to set the desired upper limit. The setting range is 20 - 50° C. Can be set in 0.1° C steps.
again to complete the process.
for approx. 3 seconds.
arrow
keys.
status light
relative humidity alarm is set to 45 %. When the humidity falls below this
relative humidity. Can be set in steps of 1 %.
will show when the Easy Breeder is