Installation
has an emptying valve. You will need separately ordered pipes between the heater and the tub
and an extra set of fixing hoses and clamps. When installing further away the heater must be
a bit lower than the tub so that the natural circulation of heated water works. Remember to
install the emptying valve and remember to empty the heater from its own valve after use.
Notice that the extension pipes should be insulated since otherwise lots of heat will be
dissipated.
Fire safety
If the heater is located near buildings, for example on
the side of a terrace, the distance of the chimney from
any
combustible
Remember to check the distance both laterally and
vertically so that there isn't any risk of fire. Safe
minimum distance, from the chimney's upper end,
laterally is three (3) meters. Shorter distance laterally is
adequate in other parts of the chimney. If the chimney
is closer to any combustible materials you must use
special insulated chimney, which has to be purchased
separately.
When positioned close to the roof or when taken
through it, the top end of the insulated chimney must be at least one (1) meter above the
surface of the roof. Ask your local fire officer for more information.
The heater is connected to the tub with rubber hoses. It
is advisable to spray silicon spray or other lubricant like
soap inside the rubber hoses to tighten the hose clamps
evenly and to prevent the hoses from wrinkling. First
connect the hoses to the pipes on the tub and add the
clamps. The clamps on the tub side can be tightened at
this point. Next you push the heater pipes inside the
hoses (picture on the left). Now tighten the clamps on
the heater side.
On an even surface, there should be approx. 20 mm of
space for the support below the stove. However, the
proper height of the support should always be checked at the
installation site.
The emptying valve is installed into the 1 ½" thread behind the heater.
Use good amount of pipe tape when installing these parts. Tighten
with pipe wrench (picture on the left).
Installation further away from the tub
This heater is suited for installation further away from the tub since it
materials
must
be
34/75
adequate.