Pujol Senior 2 Mode D'emploi page 12

Table des Matières

Publicité

ENG
Power Regulation 2 Motor Monophase Panel Senior 2
Electronic panel designed for monophase motors up to 3/4 Hp. power, for use in installations with one or two
motors. The power of the motor, smooth stop and end of operation can be regulated with the variable resistors.
Various combinations are possible with the 8 position micro switch and other selector in position 1.
The timers on the base plate are: waiting time automatic closure, opening and closure time. The timings of
opening and closure can be doubled by selection of the micro switch.
There is also a variable resistor in the base plate that regulates the motor power, another to select the time of
smooth closure, another "Def 1" for rephrasing between motor 2 and motor 1 in opening, and another "Def 2"
for dephasing between motor 1 and motor 2 in closure.
Entrances for the end of drive of the second motor and stopping of the second motor are incorporated.
All the button inputs are protected by Zener diodes and have luminous indication with Led to indicate if the
inputs are activated or no.
Possibility to add a radio card to function with remote control.
Protection
Protection of power input via 250 mA fuse and 275V varistor.
Protection of operation input via zener diode.
Protection of motors via fuse 6A
Connection of motors step by step by "o" without sparks in the relay contacts.
Installation
Make sure the mains are switched off before proceeding with the installation.
Description of connections
Power
Operation
Power 220V ac
Electro-lock 12V
Power 220V ac
Electro-lock 0V
Courtesy light
Garage light contact
Courtesy light
Garage light contact
Opening motor 1
12VDC
Closure motor 1
0VDC
General motor 1
General, FCC2, FCA2
Opening motor 2
FCC2
Closure motor 2
FCA2
General motor 2
General buttons
P.CER.
P. AB.
General FCC, FCA
FCC
FCA
CSEG
Common General buttons
PALT
N.B: N.O., Normal Opening
N.C., Normal Closure
C.L., Free Pavers Contact
Output electric lock 12VDC
Garage light contact Relay N.O.
Garage light contact Relay N.O.
Output 12V dc 125mA
Output 12V dc 125mA
Common end of drive motor 2 N.C
Input end of drive Motor Closure 2 N.C.
Input end of drive Open Motor 2 N.C
General buttons
Closure button N.O
Opening button N.O.
General end of drive motor 1
End of drive closure motor 1 N.C.
End of drive opening motor 1 N.C.
Security Contact (photocell) N.C.
General Alternative button and security contact.
Alternative button N.A.
ENG
Selection of 9 options.
Selection of options via micro-switches.
I1
ON
Tthe door closes automatically when time of green potentiometer has passed.
OFF
No automatic closure.
I2
ON
Door closes a little time before opening when it is closed.
OFF
Normal opening
I3
ON
Alternative button does not function during door opening
OFF
Alternative button normal
I4
ON
Alternative button stops and inverts operation
OFF
Alternative button stops operation
I5
ON
Deactivation of Security Contact operates door closure
OFF
Normal security contact
I6
(Without shock absorption)
ON
If the photocell is activated during opening operation and the door is detained.
OFF
If the photocell is activated during opening operation with no effect.
(With shock absorption)
ON
At the end of closure the door is pushed to assure closure.
OFF
At the end of operation there is no push.
I7
ON
Partial time, when an operation is inverted
OFF
Total time
I8
ON
Opening button works for pedestrians, opening one past 5 secs
OFF
Normal opening button, 2 parts.
I9
ON
Operating times (opening and closure) 1 to 2 mins.
OFF
Operating time 3 secs to 1 min.
Timers
Automatic closure time (green)
T. BAUT
1 sec
1 min, 30 secs
Regulates waiting time
Before operating an
Automatic closure.
Operating
The automatic operations are carried out with the button Test plate CI, or button of Alternative
connectors, or via Radio card. The opening button opens and closure button closes.
The end of operation in any of the following conditions: operation of the end corresponding drive or
end of drive time.
If an order is given during opening operation the door stops if the micro-switch 4 is OFF and stops
and inverts if ON.
Opening time (white)
Closure time (blue)
T. OPEN
T. CLOSURE
3 sec
3 sec
60 sec
(Tx2 60 secs)
(Tx2 60 secs)
(Tx2 120 secs)
Regulates oposating
Regulates operating
time of opening.
Time of closure.
60 sec
(Tx2 120 secs)