3
Type the reset password (1234567890) and press (#).
4
The buzzer intermittently sounds until resetting is complete.
5
The device is now brought back to the manufacturing conditions, all the codes have been removed.
2.4) PERSONALISATION OF ACCESS PASSWORD
1
Type the access password 123456 preset, followed by (#).
2
Type 6, the buzzer emits 2 beeps.
3
Type the new, personal password (6 digits) and press (#), the buzzer emits 3 beeps.
4
Confirm the new password by typing it a second time and press (#)
5
The buzzer emits 2 beeps to confirm the operation is complete.
3) REMOTE MODE - PROGRAMMING
IMPORTANT: In REMOTE mode, programming of the various functions takes place on the BE.REC receiver. Only the basic
functions are outlined below.
To use the advanced functions refer to the BE.REC manual, the advanced functionalities are as follows:
- Insertion of codes to scale (up to 999 accesses)
- Disabling of all codes with a certain initial digit
- Re-enabling of all codes with a certain initial digit
- Re-enabling of all disabled codes
3.1) SAVING CODES
1
Press the PGM button once on the BE.REC receiver. The LED starts to flash.
2
Type the code to save (minimum 4, maximum 9 digits), on each pressing the buzzer emits a sound to confirm typing.
3
Press the key (#), the buzzer emits a prolonged sound.
4
On the keypad, select the channel (relay) on the BE.REC receiver you intend associating the code with, keeping in mind
that:
- typing "1" you activate channel 1.
- typing "2" you activate channel 2.
- typing "3" you activate both channels (1+2).
5
Press the key (#), the buzzer emits three beeps to confirm programming.
6
The code is now saved and will activate the channel selected in point 4.