Installation Instructions – Tracer (Small / Large)
Instructions d'installation – Tracer (petit/grand)
Instrucciones de instalación – Tracer (pequeño / grande)
Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this
product must be performed by a qualified electrician. This product must be installed in accordance
with the applicable installation code by a person familiar with the construction and operation of the
product and hazards involved.
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting
any maintenance. Disconnect power at fuse or circuit breaker.
Risk of Fire- Refer to product label for specific minimum supply conductor requirements.
Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.
Risk of Personal Injury- Fixture may become damaged and/or unstable if not installed properly.
Failure to comply with these instructions may result in death, serious bodily injury and property damage.
N
otee:
These instructions do not claim to cover all details or variations in the equipment, procedure, or process
described, nor to provide directions for meeting every possible contingency during installation, operation
or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for
user's purpose, please contact your nearest representative.
Notee: Care must be taken not to set lighting fixture down on optical lenses or lift the fixture in the lens area.
Notee: Specifications and dimensions subject to change without notice.
DISCLAIMER OF LIABILITYe: Cooper Lighting Solutions assumes no liability for damages or losses of any kind
that may arise from the improper, careless, or negligent installation, handling or use of this product.
NOTICEe: Green ground wire provided in proper location. Do not relocate.
ATTENTION Receiving Departmente: Note actual fixture description of any shortage or noticeable damage on
delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be
filed within 15 days of delivery. All damaged material, complete with original packing must be retained.
Safety: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and
ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under
installation section.
APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in area
of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to
installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation
and insertion of photo control or shorting cap (if so equipped). Best results will be obtained if installed and
maintained according to the following recommendations.
WARNING
Brand Logo
reversed out of
black
Lumark
INS #
INS #

Publicité

loading

Sommaire des Matières pour LUMARK IB506017EN

  • Page 1 Brand Logo reversed out of black Lumark IB506017EN INS # INS # Installation Instructions – Tracer (Small / Large) Instructions d’installation – Tracer (petit/grand) Instrucciones de instalación – Tracer (pequeño / grande) WARNING Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product must be performed by a qualified electrician.
  • Page 2 Make wire connection in outdoor rated junction box. Use wire nuts or other approved connectors to wire fixture per wiring diagram. (Figure 3.) Snoot Visor (Included) Flat Visor (Installed) Figure 4. Figure 2. COOPER LIGHTING SOLUTIONS IB506017EN Installation instructions...
  • Page 3 N’exposez pas le luminaire à la pluie, à la poussière ou à d’autres conditions ambiantes avant l’installation et l’insertion de l’interrupteur photo-électrique ou de la fiche de mise en court-circuit (si équipés). Pour de meilleurs résultats, respectez les recommandations d’installation et d’entretien suivantes. COOPER LIGHTING SOLUTIONS IB506017EN Instructions d’installation...
  • Page 4 être utilisée à l’extérieur. Utilisez Coupe-flux de des capuchons de connexion ou autres connecteurs viseur (fournie) approuvés pour le câblage du luminaire selon le schéma de câblage. (Figure 3.) Plate de viseur (installée) Figure 4. Figure 2. COOPER LIGHTING SOLUTIONS IB506017EN Instructions d’installation...
  • Page 5 (si está equipado). Los mejores resultados se obtendrán si se instala y se mantiene de acuerdo con las siguientes recomendaciones. COOPER LIGHTING SOLUTIONS IB506017EN Instrucciones de instalación...
  • Page 6: Herramientas Necesarias

    Use tuercas de alambre u otros conectores aprobados para cablear la luminaria según el diagrama de cableado. (Figura 3.) Snoot del visor (Incluido) Plano del visor (instalado) Figura 4. Figura 2. COOPER LIGHTING SOLUTIONS IB506017EN Instrucciones de instalación...
  • Page 7 Imprimé aux États-Unis Cooper Lighting Solutions es una Impreso en los EE. UU. marca comercial registrada. Todas las La disponibilidad de productos, las IB506017EN Publication No. marcas comerciales son propiedad de especificaciones y los cumplimientos May 6, 2019 sus respectivos propietarios.