NATURAL GAS CONVERSION
Before operating your grill, after refueling, check carefully to be certain that all connections are
tight and there are no gas leaks.
1. Make 2-3 ounces of leak solution by mixing liquid dishwashing soap with water.
2. Make certain all control knobs are in the "OFF" position.
3. Brush small amounts of the leak solution on all the fittings and turn the gas on.
4. If bubbles appear, there is a leak. Proceed to step 5.
5. Turn the gas off and tighten all connections.
6. Go back to step 1 to retest the fittings.
7. If bubbles continue to appear, turn the gas off. Contact customer service.
IMPORTANT: Checking the GENERAL MAINTENANCE on Page 30 after finished the conversion.
21. Removed the R-pins at the back of main
burners to detach burners from bracket. Lift
back of burners while sliding burners out of
firebox, disengaging burners from gas
valves as shown.
22. Unscrew the old LP orifice from each gas
valve with the orifice removal tool. Put a
new NG orifice onto the valves and tighten
with tool. Repeat this step for all four main
burners.
φ1.30mm Orifice
Orifice removal tool
 
x4
x1
18
21
 
1
2
 
22
1