CONSUMER: READ AND SAVE THESE INSTRUCTIONS
Locating Your Serial Number:
Your serial number can be found in the bottom left hand corner of the heater's instruction hang-
tag. It will begin with the letters "PGTT" followed by 8 digits. For Example: PGTT12345678.
Have your Serial Number ready before calling customer service at 800-641-6996.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY FOR:
The temporary heating of adequately ventilated buildings or
structures under construction, alteration or repair.
GENERAL HAZARD WARNING:
DANGER
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS
HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE
FROM HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, AND/OR CARBON MONOXIDE
POISONING.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE
OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS
AN INSTRUCTIONS MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUS-
WARNING
TIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DIS-
TANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INSTRUCTIONS. NEVER USE
THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTI-
BLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES OR
UNKNOWN CHEMICALS.
MODEL NUMBERS
REM-16-TTC-B / REM-32-TTC-B / REM-47-TTC-B
Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
© 2018 Pinnacle Climate Technologies, Inc.
PROPANE TANK TOP
HEATER
User's Manual &
Operating Instructions
Factory ID: 522
RBTA-402

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Pinnacle Climate Technologies Remington REM-16-TTC-B

  • Page 1 BLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS. 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996 Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com © 2018 Pinnacle Climate Technologies, Inc. RBTA-402...
  • Page 2: Table Des Matières

    ANSI Z83.7-2011/CSA 2.14-2011. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS. Other standards govern the use of fuel gasses and heating products for specific uses. Your local authority can advise you about these. © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 3: Safety Information

    (2,800 sq cm) opening of outside air for every 100,000 Btu / Hr heater rating. Refer to “Ventilation” on page 11 for further instructions. © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 4 ANSI/NFPA 58 and the Natural Gas and Propane Installation Code CSA B149.1. RISK OF FIRE! ALWAYS ATTACH THE HEATER IN AN UPRIGHT VERTICAL WARNING POSITION. ALWAYS LOCATE HEATER ON A STABLE AND LEVEL SURFACE! © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 5: Specifications

    620 / 700 / 800 900 / 1000 / 1175 Specifications subject to change without notice. FEATURES REM-16-TTC-B Rear Guard Front Guard Ignition Hole Heat Reflector Tip Over Switch Regulator Safety Valve © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 6: Features

    Safety Valve Regulator Tip Over Switch Mounting Bolt Knob REM-47-TTC-B Rear Guard Heat Reflector Front Guard Ignition Hole Safety Valve Hose Tip Over Switch Mounting Bolt Knob Regulator © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 7: What's In The Box

    WHAT’S IN THE BOX REM-16-TTC-B (1) Mount and Unit with Single Burner Head REM-32-TTC-B (1) Unit with Two Burner (1) Mount Heads REM-47-TTC-B (1) Unit with Three Burner (1) Mount Heads © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 8: Assembly

    Knob Mounting Bolt Knob Fuel Connector Nut Tank Collar Bracket Manifold Fuel Connector Nut Swivel Bracket Regulator Mounting Bolt Knob Knob Tank Collar Bracket Figure 1 Figure 2 © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 9 DO NOT direct the heater dis- not to over tighten. WARNING charge towards any propane 3. Slowly open the LP cylinder valve. cylinder located within 20 feet of the heater. © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 10: Operation

    – A safety relief valve having direct communications with the vapor space of the LP cylinder. – The heater must operate on vapor withdrawal from the operating cylinder. © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 11: Danger

    ALWAYS stand to the side or rear of the heater Heat Regulator Knob during ignition. DO NOT allow any body part to touch the heater or be in front of the heater during ignition. Figure 4 © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 12: Maintenance And Storage

    5 of the Standard manufacturers part. Heater should be for Storage and Handling of Liquefied inspected before each use and once annually Petroleum Gases (ANSI/INFPA 58). by a qualified service person. © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 13: Troubleshooting Guide

    2. Replace Burner screen. glowing red. Flames 3. Gap between burner screen 3. Replace or repair burner head flashback / burn inside and burner can. assembly. the mixing tube. © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 14: Exploded View

    EXPLODED VIEW PARTS LIST Item Description REM-16-TTC-B REM-32-TTC-B REM-47-TTC-B Hose Assembly – 20-051-0001 20-051-0002 Thermocouple 20-091-0002 20-091-0002 20-091-0002 Mounting Bolt Knob – 20-503-0001 20-503-0001 Tipover Switch 50-017-0001 50-017-0001 50-017-0001 © 2018 Pinnacle Climate Technologies, Inc. Propane Tank Top Heater User’s Manual...
  • Page 15 FOR A PARTICULAR APPLICATION. FURTHER, Pinnacle use and service within the warranty period, and which Climate Technologies, Inc. SHALL HAVE NO LIABILITY Pinnacle Climate Technologies, Inc. shall determine at its WHATSOEVER TO PURCHASER OR ANY THIRD PARTY reasonable discretion. FOR ANY SPECIAL, INDIRECT, PUNITIVE INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
  • Page 16 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996 Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com © 2018 Pinnacle Climate Technologies, Inc.
  • Page 17: Chaufferette Sur Bouteille De Propane

    DES PARTICULES DE POUSSIÈRE OU DES PRODUITS CHIMIQUES INCONNUS. 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Numéro sans frais (800) 641-6996 Télécopieur : 320 251-2922 • Web : www.remingtonheater.com • Courriel : info@pinnacleclimate.com © 2018, Pinnacle Climate Technologies, Inc.
  • Page 18 VÉRIFIER AVEC LE SERVICE LOCAL DES INCENDIES EN CAS DE QUESTIONS SUR L’APPLICATION. D’autres normes régissent l’utilisation des gaz combustibles et des produits de chauffage pour des utilisations spécifiques. Les autorités locales peuvent vous informer sur ces dernières. © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 19: Consignes De Sécurité

    NE JAMAIS utiliser la chaufferette dans une tente. (100 000 BTU/h) du régime nominal de l’appareil. Voir la section « Ventilation » à la page 11 pour plus de détails. © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 20 CSA B149.1. RISQUE D’INCENDIE! TOUJOURS FIXER LA CHAUFFERETTE DANS UNE POSITION AVERTISSEMENT VERTICALE. TOUJOURS PLACER LA CHAUFFERETTE SUR UNE SURFACE PLANE ET STABLE. © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 21: Specifications

    Spécifications sujettes à modification sans préavis. CARACTÉRISTIQUES REM-16-TTC-B Protecteur arrière Protection avant Orifice d’allumage Réflecteur de chaleur Interrupteur anti- basculement Régulateur Robinet de sécurité © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 22: Caractéristiques (Suite)

    Bouton du boulon de montage REM-47-TTC-B Protecteur arrière Réflecteur de chaleur Protection avant Orifice d’allumage Robinet de sécurité Tuyau Interrupteur anti-basculement Bouton du boulon de montage Régulateur © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 23: Contenu De La Boîte

    (1) Support de montage et unité avec brûleur simple REM-32-TTC-B (1) Unité avec deux brûleurs (1) Support de montage REM-47-TTC-B (1) Support de montage (1) Unité avec trois brûleurs © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 24: Montage

    Bouton du Bouton du boulon de montage régulateur Support du manchon de bouteille Figure 1 Figure 2 © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 25 3. Ouvrir lentement le robinet de la bouteille de GPL. AVERTISSEMENT pas être dirigée vers un quelconque contenant de gaz propane situé dans un rayon de moins de 6 mètres. © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 26: Mode D'emploi

    Une soupape de sûreté en communication directe avec l’espace de vapeur de la bouteille. – La chaufferette doit fonctionner à partir du gaz provenant de la bouteille d’alimentation. © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 27 NE laisser AUCUNE partie du corps entrer en contact avec Figure 4 l’appareil et NE PAS se tenir devant lors de l’allumage. © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 28: Entretien Et Entreposage

    Storage and Handling of Liquefied Petroleum par un technicien d’entretien qualifié. Gases (ANSI/INFPA 58). © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 29: Guide De Dépannage

    Retour de flammes/ 3. Écart entre le brûleur et le pot du 3. Remplacer ou réparer la tête du Combustion dans le tube brûleur. brûleur. mélangeur. © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 30: Vue Éclatée

    REM-32-TTC-B REM-47-TTC-B réf. Tuyau – 20-051-0001 20-051-0002 Thermocouple 20-091-0002 20-091-0002 20-091-0002 Bouton du boulon de montage – 20-503-0001 20-503-0001 Interrupteur anti-basculement 50-017-0001 50-017-0001 50-017-0001 © 2018, Pinnacle Climate Technologies, Inc. Manuel de l’utilisateur de la chaufferette sur bouteille de propane...
  • Page 31: Garantie Limitée

    UN USAGE PARTICULIER. EN OUTRE, Pinnacle Climate et d’entretien normales pendant la période de garantie, ce Technologies, Inc. N’EST AUCUNEMENT RESPONSABLE que Pinnacle Climate Technologies, Inc. se réserve le droit de déterminer à sa seule discrétion. ENVERS L’ACHETEUR NI ENVERS TOUT TIERS POUR UN QUELCONQUE DOMMAGE PARTICULIER, INDIRECT, PUNITIF, ACCESSOIRE OU FORTUIT.
  • Page 32 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Numéro sans frais (800) 641-6996 Télécopieur : 320 251-2922 • Web : www.remingtonheater.com • Courriel : info@pinnacleclimate.com © 2018, Pinnacle Climate Technologies, Inc.