Electrical Connections; 3-Wire Branch Circuit (For Us Only) - Fulgor Milano F4SP30 3 Série Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CAUTION
• Do not repair or replace any part of the appliance
unless specifically recommended in the manual. All other
servicing should be done by a qualified technician. This
may reduce the risk of personal injury and damage to
the oven.
• Never modify or alter the construction of the appliance by
removing panels, wire covers, screws, or any other part
of the product.

Electrical Connections

Be sure your appliance is properly installed and grounded by
a qualied technician. Ask your dealer to recommend a qualied
technician or an authorized repair service.
This appliance is manufactured with a green GROUND wire
connected to the oven chassis. After making sure that the
power has been turned o, connect the exible conduit from the
oven to the junction box using a U.L. listed conduit connector.
Figures A and B and the instructions provided below present
the most common way of connecting the ovens.
Your local codes and ordinances, of course, take precedence
over these instructions. Complete electrical connections
according to local codes and ordinances "WARNING" Risk of
Electric Shock, frame grounded to neutral of appliance through
a link .
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or in an area where local codes prohibit
grounding through the neutral conductor. For installations
where grounding through the neutral conductor is prohibited:
• Disconnect the ground from the neutral at free end of
conduit;
• Use grounding terminal or lead to ground unit; and
• Connect neutral terminal or lead to branch circuit neutral in
usual manner.

3-Wire Branch Circuit (For Us Only)

Refer to Figure A, where local codes allow the connection of
GROUND wire from the oven to the branch circuit NEUTRAL
wire (gray or white colored wire):
• If local codes permit, connect the green GROUND wire
from the oven and the white wire from the oven to the
branch circuit NEUTRAL wire (gray or white colored wire).
• Connect the red and black leads from the oven to the
corresponding HOT Wires in the junction box.
• Connect the local codes and power supply codes using a
terminal.
• The terminal uses a thing adapting to the wire of the cord.
GROUNDED NEUTRAL
A
Junction box
power supply
Red wires
White wires
Bare or
green wire
Cable
from oven
Cable from
Black wires
UL listed conduit
connector