Please Note; Error Message - effegibi Touch&Steam Manuel D'utilisation

Masquer les pouces Voir aussi pour Touch&Steam:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
TOUCH&STEAM OPERATING AND MAINTENANCE MANUAL
TROUBLE-SHOOTING
PLEASE NOTE: the information in the table below and the action to take is intended for the
use of the assistance centre personnel and others qualified to install/maintain the equipment.

Error message

Error Led 1
Error Led 2
Error Led 3
Error Led 4
Error Led 5
26
The data and features referred to are not binding on EFFEGIBI and the company reserves the right to make any appropriate changes
Meaning
Error
The boiler filled
Boiler
full
too
too quickly during
soon.
initial rinsing or final
emptying.
The boiler didn't fill
within the prescribed
Boiler not yet full.
time
limit
initial rinsing or final
emptying.
Lack of
Communication
communication with 1
error.
or more devices.
The water level in
the boiler remained
Boiler
not
yet
too high for too long
empty.
during initial rinsing or
final emptying.
Te m p e r a t u r e
probe
error
without having to give prior warning or replace this manual.
Cause
Outlet valve not
working.
Lack of water in
the system or the
during
inlet valve filter is
blocked.
One of the devices
is
not
receiving
power or is not
connected.
Outlet
valve
not
working.
Problem with the
panel temperature
probe.
Solution
1. Check that the outlet path is
clear.
2. Check that the steam pipe is
not obstructed, bent or is not
siphoning.
3. Clean the outlet valve.
1. Check that the water tap is
turned on.
2. Check that there is water in
the system.
3. Check that the filter at the
entrance to the inlet valve is not
blocked.
1. Check the device
connections.
2. Run the start-up sequence.
1. Check that the outlet path is
clear.
2. Check that the steam pipe is
not obstructed, bent or is not
siphoning.
3. Clean the outlet valve.
Contact the service centre

Publicité

Chapitres

Table des Matières
loading

Table des Matières