Adjusting the temperature:

To set or check the set-point temperature (with the control
out of sleep mode), press the "-" or "+" keypads. "SET" will
be indicated on the user interface panel and the current
set-point temperature will display and flash. Subsequent
presses of the "-" or "+" keypads will adjust the temperature
colder or warmer respectively. When you have reached
your desired set-point temperature, press the "On/Off" key-
pad to accept, or do nothing and the "Set" mode will time-
out in 10-seconds accepting the displayed temperature as
the new set-point.
The available set-point temperature range for your ap-
pliance is 34°F (1.2°C) to 42°F (5.7°C). If you attempt to
adjust the temperature outside of this range you will receive
an audible notification.
When initially loading your product with warm contents, it
may take up to 48-hours for the storage compartment tem-
perature to stabilize.
When making temperature set-point changes, it may take
up to 24-hours for the stored contents to stabilize at your
new set-point temperature.
Factors that affect the storage compartment stabilized
temperature:
Changes to temperature setting.
Room temperature changes.
Temperature of stored contents.
- Loading warm contents.
- Cold content load will delay the change to a warmer
set-point temperature.
- Warm content load will delay the change to a colder
set-point temperature.
Usage, (number and duration of the drawer openings).
Installation of the appliance in direct sunlight or next to
a heat source.
USING YOUR ELECTRONIC CONTROL

Temperature mode:

The temperature mode is preset from the factory in Fahren-
heit (°F) but you have the option to change it to Centigrade
(°C). To change the mode, press and hold the "-" keypad,
while pressing the "+" keypad, then release the "-" keypad.
The temperature will now be displayed in Centigrade (°C).
Repeat the procedure to change the temperature mode
back to Fahrenheit (°F).

Control lock:

The control panel can be locked to avoid unintentional
changes. To lock the control, press and hold the "Lock" key-
pad until the display reads "Loc" then release your finger
from the keypad. The lock icon will flash 3-times and then
continuously illuminate. When the control panel is locked,
only the Lock keypad, System Status OK indicator , and
the Alarm indicator are active. To un-lock the control panel,
repeat this instruction until the display reads "nLc".

Alarms:

The control will alert you to conditions that could adversely
affect the performance of the appliance.
Door Ajar
• Door ajar -
If a drawer is open, or not closed prop-
erly, for more than 5-minutes the System Status OK
indicator will turn-off, the "Door Ajar" indicator will flash,
and a tone will sound every 60 seconds. Additionally,
an "ALARM RESET" indicator will be displayed below
the "On/Off" keypad. This alarm condition can be reset
by closing the drawer or momentarily pressing the "On/
Off" keypad, (i.e.-if you are cleaning the storage com-
partment, etc.). The alarm will recur in 5-minutes if the
alarm condition persists.