1.1
rating plate information
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2016, CERTIFIED TO / CERTIFIE CSA 2.22-2016
9700539 (WSL)
4001659 (WUSA)
4001658 (NAC)
4001657 (NGZ)
MODEL NATURAL GAS/GAZ NATURAL
DIRECT VENT
B-VENT
GDS60-1N
GS60-1N
CDVS600-1N
CS600-1N
TOP VENT
REAR VENT
0-4500
0-4500
0-4500
35,000
*21,000
35,000
21,000
12,000
21,000
REDUCED INPUT(BTU/H)ALIMENTATION REDUITE
24,500
*14,700
63.1%
*WHEN VENTING OFF THE REAR OF THE UNIT AND TERMINATING HORIZONTALLY
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C. (LP)
PRESSION AU COLLECTEUR: 3.5" (GN) / 10" (PG) D'UNE COLONNE DEAU
MIN SUPPLY PRESSURE: 4.5" W.C. (NG) / 11" (LP)
PRESSION D'ALIMENTATION MIN: 4.5" (GN) / 11" (PG) D'UNE COLONNE
D'EAU
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 7" (GN) / 13" (PG) D'UNE COLONNE D'EAU
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENT AVEC
CETTE UNITE.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL
COME IN CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY
THE MANUFACTURER WITH THE APPLIANCE.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
OPTIONALBLOWER KIT / ENSEMBLE DE
VENTILATEUR FACULTATIF: GS64-KT
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
1.2
dimensions
SAFETY BARRIER
VENTED DECORATIVE GAS APPLIANCE / FOYER À GAZ VENTILÉ.
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT
PAS ETRE UTILISE AVEC CET APPAREIL
MODEL PROPANE/PROPANE MODÈLE
B-VENT
GS60-1P
CS600-1P
ALTITUDE(FT/PT)ELEVATION
0-4500
INPUT(BTU/H)ALIMENTATION
31,500
22,000
OUTPUT(BTU/H)RENDEMENT
P4
63.1%
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN
MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE
QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
PRODUIT DÉCORATIF: NE PAS UTI;ISER COMME APPARIEL DE
CHAUFFAGE
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL / DEGAGEMENTS
MINIMAUX DES MATERIAUX COMBUSTIBLES:
A
6"
B
6"
C
2"
20" TO CEILING FROM STOVE TOP
.
1" TO DIRECT VENT AND B-VENT / L'EVACUATION DIRECTE &
L'EVACUATION B
6" TO C-VENT/ A L'EVACUATION C
20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND
ELECTRICAL RATING/CLASS: 115V 1.5AMP 60HZ
37"
940mm
30 1/2"
775mm
17 7/8" 454mm
19 1/2" 495mm
general information
MODEL CDVS600-1/GDS60-1 APPROVED FOR BEDROOM, BATHROOM & BEDSITTING
ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN
ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED
MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US
STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A. FOR
USE WITH BARRIER W010-3296. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED
IN THE INSTALLATION MANUAL.
DIRECT VENT
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE
GDS60-1P
BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
CDVS600-1P
INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE
MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE
TOP VENT REAR VENT
LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE
24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE
0-4500
0-4500
APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE
31,500
*21,000
SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS
22,000
*13,000
MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. POUR UNE
22,050
*14,700
UTILISER AVEC BARRIÈRE W010-3296. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE
TROUVENT DANS LE MANUEL D'INSTALLATION.
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET
RESPECTIVELY FOR TOP VENTED UNITS AND 13 INCHES AND 20 FEET RESPECTIVELY
FOR REAR VENTED UNITS.
LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS
RESPECTIVEMENT POUR UN EVACUATION VERTICALE ET 13 POUCES ET 20 PIEDS
RESPECTIVEMENT POUR UN EVACUATION HORIZONTALE.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS. SEE
OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS.
PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE
VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE
A NAPOLEON. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER
L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
MODEL CS600-1/GS60-1
APPROVED FOR BEDROOM, & BEDSITTING ROOM INSTALLATION. HOMOLOGUE POUR
INSTALLATION DANS UNE CHAMBRE A COUCHER, & UN STUDIO. THIS APPLIANCE MUST
BE INSTALLED USING AN ADAPTER KIT GS-150KT. CET APPAREIL DOIT ETRE INSTALLE
EN UTILISANT UN ENSEMBLE ADAPTATEUR GS-150KT.
SERIAL NUMBER
NO. DE SERIE
24"
610mm
27" 686mm
GDS60
W385-1961 / B
4" 102mm DIA.
7" 178mm DIA.
5 1/2" 140mm
W415-1330 / B / 12.06.18
EN
7