1.0 general information

When the appliance is installed at elevations above 4,500ft (1371m), and in the absence of specifi c recommendations from
the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each ad-
ditional 1,000ft (305m).
Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in propane.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certifi ed kit is used.
CDVS600-1 - This appliance is not approved for closet or recessed installations. It is approved for bathroom,
bedroom and bedsitting room installations. This appliance may be installed in an aftermarket permanently located,
manufactured (mobile) home, where not prohibited by local codes. (Rear vent) Rear exit installations which termi-
nate horizontally and have no vertical vent runs must have the BTU input reduced to 21,000 BTU/hr by changing
the orifi ce (supplied).
CS600-1- This appliance is approved for bedroom and bed-sitting room installations.
Altitude (FT)
Max. Input (BTU/
HR)
21, 000 (Rear vent only)
Max. Output (BTU/
HR)
Max. Steady State
Effi ciency (w/the
fan on)
Max. A.F.U.E.
Min. Inlet Gas
Supply Pressure
Max. Inlet Gas
Supply Pressure
Manifold Pressure
(Under Flow
Conditions)
Installer, please fi ll out the following information:
Propane:
CDVS600-1
NG
0-4,500
35,000 (Top vent)
21,000 (Rear vent only)
27,300
78%
72%
4.5" (11mb)
Water Column
7" (17mb)
Water Column
3.5" (9mb)
Water Column
standard checklist
CDVS600-1P
CS600-1P
P
0-4500
31,500 (Top vent)
24,570
78%
71%
11" (27mb)
4.5" (11mb)
Water Column
Water Column
13" (32mb) W
ater Column
Water Column
10" (25mb)
Water Column
Water Column
CS600-1
NG
P
0-4500
0-4500
35, 000
31,500
27,300
24,570
78%
78%
72%
71%
11" (27mb)
Water Column
7" (17mb)
13" (32mb)
Water Column
3.5" (9mb)
10" (25mb)
Water Column
W415-1330 / B / 12.06.18
EN
5