setting the filtration and underWater light timer
a
a - Lift the transparent window to gain access to the timer setting thumb wheel.
b - Set the time by turning the dial in the direction of the arrow until the current time is positioned opposite the contact
tab (8:00 am in this example).
c - Programme the running times by pushing the segments on dial inwards. Each segment represents a 30 minute
interval.
Example: To program a 3 hour running cycle, push 6 consecutive segments inwards.
d - Make sure that the selection switch is set to 
Caution: Never rotate the thumb wheel in the direction opposite to that indicated by the arrow.
Position " I " .......: Filtration/ underwater lights on continuously.
Position "  " .......: Filtration/ underwater lights come on during the programmed operating cycles.
To shut down filtration/ underwater lights permanently, remove the fuse (this will also cause the timer to stop).