- The control panel must be installed in accordance with the conditions set out in the standard C15-100, part 7,
chapter 702. For this reason, installation should be entrusted to an accredited professional.
- The control panel should be mounted on a wall or vertical partition capable of bearing the load.
- The control panel should be installed :
- either outside volumes 0, 1 and 2 (see figures 1 to 4 on the following pages).
- or in a closed plant room accessible only through a door or man hole. This configuration is only authorised if the
door or manhole is secured by a lock.
- Irrespective of the installation configuration, the control panel power supply must be protected upstream by a 30 mA
differential circuit breaker.
- Before any intervention requiring removal of the front panel, make sure that the power supply has been shut off
upstream from the control panel.
- A means of disconnection must be installed in accordance with the rules covering installation in the country of
installation.
- The fuse should only be replaced with a fuse that has the same rating.
- Voltage ....................... : 230 volts 1ph
- Frequency .................. : 50 Hz
- Maximum current ....... : 4 A
overvieW
Transformer
12 V / 100 VA
Fuse 10 A
Filtration
contactor
Fuse 4A
Filtration timer
4A
10/16
Underwater light
Filtration circuit
Power supply
2014/05 - Indice de révision : B - Code : 0032625
timer
breaker
230 V 1ph