8.2
Changing the nozzle
Proceed as follows:
•
Ensure that the plasma generator is disconnected from the power supply.
•
Press the stop buttons on both sides of the nozzle insert.
•
Pull the nozzle insert out of the housing.
•
Put the new nozzle insert in the housing. If necessary, press the stop buttons initially
and do not angle the insert.
•
Apply a little pressure and slide the nozzle insert in until it engages in the lock position.
Attention – Damage to device!
Never touch the piezo crystal on the front side of the device with sharp-edged objects.
This component may be damaged by improper handling.
9
Troubleshooting
Fault / error
Device cannot be started or
plasma stops during operation
If these actions do not remedy the problem, please contact customer service.
Cause
Mains failure
Mains fuse triggered.
Mains plug not making contact
correctly.
Mains plug is defective.
There is an internal error.
Piezo crystal broken, the
plasma generator is defective.
Shutdown due to overheating.
Troubleshooting
Rectification
(provided by customer).
Check mains fuse.
Check seat of mains plug.
Replace mains plug.
De-energise device. Switch on
again.
Contact customer service.
Allow the plasma generator to
cool down. Ensure that the fan
grille is not covered so that
enough ambient air can be
drawn in.
11