– The device measures the presence of electrostatic fields of
sufficient strength. If the field strength is too low voltage may
still be applied although no warning signal is given. The following
list of factors that influence the field strength does not claim to
be complete: shielding, cable insulation (type, thickness), measure-
ment distance, insulation between user and earth, special socket
designs, condition of tester and of batteries.
Safety instructions
Dealing with electromagnetic radiation and electromagnetic disruptions
– The measuring device complies with electromagnetic compatibility
regulations and limit values in accordance with EMC-Directive
2014/30/EU.
– The measuring device complies with safety and electromagnetic
compatibility regulations and limit values in accordance with
Directive 2014/35/EU (Low Voltage Directive / LVD) and 2014/30/EU
(Electromagnetic Compatibility Directive / EMC).
– Umarex GmbH & Co. KG hereby declares that the ActivePen
complies with the essential requirements and other provisions
of the European Low Voltage Directive 2014/35/EU (LVD) and
the Electromagnetic Compatibility Directive 2014/30/EU.
The EU Declaration of Conformity can be found in its entirety
at the following address: http://laserliner.com/info?an=AAG
– Local operating restrictions – for example, in hospitals, aircraft,
petrol stations or in the vicinity of people with pacemakers –
may apply. Electronic devices can potentially cause hazards
or interference or be subject to hazards or interference.
Symbols
Warning about hazardous electrical voltage:
Unprotected live components inside the device
housing are capable of posing a risk of electric
shock.
Protection class II: The test device has reinforced
or double insulation.
Overvoltage category III: Equipment in fixed
installations and for applications where specific
requirements with regard to the reliability and
availability of equipment have to be met, e.g.
circuit-breakers in fixed installations and devices
used in industrial applications which are
permanently connected to the fixed installation.