Important:
The electric strike plate or lock that you install must be equipped with a mechanical memory. For
wiring, refer to the label on the back of the camera.
c. Connecting a gate motor (fig. 6)
Directly connect the gate motor wires to terminals 3 and 4 on the back of the camera. The camera provides a
'dry'-contact connection, without an electric current, to connect to the button for your automated gate.
Note that this function is only valid if the screen is on.
6. USER MANUAL
Important:
The touch-sensitive buttons must be used with fingers only.
a. Using the video intercom
• When someone presses the button on the exterior panel, a sound goes off inside and the monitor turns on for
about 30 seconds. Once you have identified the visitor, press the
Note: One press of the
• When your conversation is finished, wait for the end of the timer (about 2 min.) or press the
to turn off the monitor.
• To bring back the video feed:
To bring back the video feed for an extra 30 seconds, press the
• Control of an electric strike plate:
The strike plate or lock is opened when your press the
• Control of an automated gate:
To control an automated gate, press the
Note that gate opening functions are only valid if the screen is on. When the opening command is
given, the video briefly cuts out.
b. Video intercom settings (fig. 2)
Four settings can be found on the side of the monitor:
• Ringtone selection (9).
• Ringtone volume setting (6).
• Brightness setting (7).
• Colour setting (8).
7. TECHNICAL CHARACTERISTICS
a. Monitor
• Power supply: 17 V
• Consumption: 6.8 W
• 7" (18 cm) screen
• Resolution: 480 x 234 points
• Dimensions (mm): 180 x 180 x 20