OPERATION CHECKLIST

Check all hose connections.
Use a 12 gauge cord if the cord is shorter than 50 ft (15 m) or a 10 gauge
cord if the cord is longer than 50 ft (15 m).
Provide fresh air intake for the cooler and maintain a minimum clearance
of 3 ft (0.9 m) behind the cooler. Do not operate the cooler in an enclosed
space.
Make sure the the water source does not exceed 120 PSI of water pressure.
Make sure the cooler's reservoir is filled with water before turning on the
pump. The pump automatically shuts off if the water level is too low.
Flush new cooling media.
1.
Fill the cooler with water.
2.
Turn on the pump.
3.
Run the cooler without the fan running for 5 hours.
Make sure the cooling media is evenly saturated.
Dry out the cooling media before shutting down the cooler. Turn off the
pump and leave the fan running for 10 to 15 minutes.
Drain and clean the cooler weekly. Remove the cooling media and rinse with
a garden hose.
To avoid scale and mineral buildup, use water treatment tablets periodically.
One tablet is provided in the cooler's reservoir. Every 3 months, add 1 tablet
to the reservoir after cleaning. Additional tablets are available by calling
877-244-3267.