same House Code. To solve this problem try to change the House Code of your system, or
have FD10 Phase Coupler/Filter installed at your incoming mains.
My modules will not respond to my controller.
Make sure that the House Code on all Modules and Controllers are set to the same House
Code (A .. P).
My modules will not react to my remote / sensor.
When you use a remote or sensor, you should have at least one TM13 Transceiver or
Marmitek Security Console installed in your house. These components will translate the radio
signals to the Marmitek X-10 signal on the power line. Only one Transceiver should be
installed for all remotes and sensors set to the same House Code.
Am I able to increase the range of my remotes by using more Transceivers?
Yes, you can use more than one TM13 Transceiver in your home when the range of your
remotes is not sufficient. The TM13 is using so called collision detection to prevent signals to
be disturbed when more than one TM13 is transmitting. TM13's will wait for a quite power
line before transmitting their data. To prevent your Marmitek X-10 System to become slow or
to prevent dimming from becoming less smooth, make sure that the TM13 units are placed as
far away from each other as possible.
USER INSTRUCTIONS LD11 DIN RAIL DIMMER
SWITCH OFF APPROPRIATE MAINS FUSE AND MASTER SWITCH!
(INSTALLATION BY A CERTIFIED INSTALLER)

Technical data

Supply voltage:
Supply current :
Making capacity:
Control time:
Fuse:
Signal sensitivity:
Input impedance:
Connection:
Ambient temperature:
Dimensions:
LD11
TM
1. Mount the LD11 using the schematics below.
2. Set the rotary code switches on the front side to the
desired address.
When mounting more LD11 dimmers next to each other,
depending on the load per LD11, keep an extra distance of 2
cm between each LD11 to ensure the heat dissipation.
With the help of additional momentary switches on input 2,
the module can be switched on or off by a short key press and
can be dimmed by a long key press.
230V +10% -15% 50 Hz
< 20 mA capacitive
40W/230V to 700W/230V for incandescent lamps and low voltage
halogen lights with transformer.
Soft start and soft dim. Memory function for last dimmer setting.
3.5 sec. ± 0.2 sec. from completely on (100%) to off (0%)
2.5 A (T)
15 mVpp min 50 mVpp max at 120 kHz
> 60 Ohm (L - N) at 120 kHz
Connecting clamps for phase, neutral, switched phase and
pressure pulse switch
- 10° C to + 50° C (operation) - 20° C to + 70° C (storage)
50x80x70mm