electrical information
EN
4.3

hard-wiring introduction and preparation

WARNING
!
Turn off the appliance completely and let cool before servicing. Only a qualified person should service and repair
this electric appliance.
HARD-WIRING CONNECTION
It is necessary to hard-wire this appliance. A qualified electrician must wire the appliance directly to the household
wiring. The wire and power supply breaker must be rated for 120V, minimum 15 amps.
This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local
codes, with the latest edition of the National Electrical Code ANSI/NFPA 70 in the United States or the Canadian
Electrical Code CSA C22.1 in Canada.
1. Locate the desired 14/2 or 14/3 wire conductors to the top right side of the enclosure for the hard-wiring
installation based on the desired 120V or 240V heat output capability.
2. Remove the junction box cover.
3. Place the appliance into the rough-in framing, inserting it far enough into the enclosure to locate the supply
wires to the terminal block.
4. Insert the wires from your home through the junction box cover plate with the strain relief (supplied) and locate
the wires to the specified terminal block location based on desired voltage selection (Fig. 4-1 or 4-3).
4.4

120V hard-wiring

1. Ensure the factory-installed jumper wires join terminals 13 to 16, 14 to 15, and 11 to 19.
2. Insert the ground/bond wire into terminal 22, and L1 wire into terminal 12.
3. Loosen terminal 19. Insert the Supply neutral wire into terminal 19 along with the jumper wire that connects to
terminal 11 (Fig. 4-2).
4. Re-install the junction box cover plate.
D x 1
B
Appliance
18
W415-1953 / C / 03.04.21
Junction Box
Cover Plate
Strain Relief
Inside
Outside
Appliance
120V AC
G
N
22
21
20
19
18 17
JUMPER WIRE LOCATIONS VARY FOR 120V
AND 240V.
LES EMPLACEMENTS DU FIL DE DÉRIVATIONS
VARIENT DE 120V ET 240V.
Fig. 4-1
L1 N
16
15
14
13
12
11
Fig. 4-2
W385-2365 / B