1. General

Installation and service by qualified personnel only

1.1 Applications

The multistage selfpriming pump is suitable for clear or slightly muddy
water, condensate, water/glycol mixtures up to a ratio of 35 % glycol as
well as other liquids free from mineral oil and without abrasives or long-
fibred
substances.
Specially
conjunction with rain water utilization.
The main areas of use are in rain water utilization systems, water
supply installations, in cooling water systems and in washing and
sprinkler installations.
Selfpriming pumps must not be directly connected to the public water
supply system.

1.2 Technical description

1.2.1 Performance and electrical data
AC voltage:
1 ~ 230 V (±10%)/50Hz or
220 V (-10%)/60Hz - 240 V (+6%)/60Hz
Rotary current voltage:
3 ~ 230/400 V (±10%)/50 Hz or
220/380 V (-10%)/60 Hz - 265/460 V (+10%)/60 Hz
Motor power:
Maximum current:
Fluid temperature:
Max. permissible working pressure: 8 bar,
Min./Max. permissible inlet pressure: –0.8/4 bar,
Max. suction head (SH):
Max. ambient temperature:
Protective system:
Other voltages/frequencies are optional and/or available on request.
When pumping viscous fluids (e.g. water/glycol mixtures) adjust the
pump data to allow for the higher viscosity.
Only use branded glycol mixtures with corrosion inhibitors and follow
the manufacturers instructions.
For dimensions see table and Fig. 4.
Pump
Model
H
1~
3~
MC
304
216
192
305
216
192
604
216
192
605
224
206
When ordering spare parts, please give all the information of the rating plate.
suited
for
use
see rating plate,
see rating plate,
+5 °C to +35 °C
8 m
40 °C,
IP 54.
H1
L
L1
90
423
253
90
447
277
90
423
253
90
472
277
1.2.2 Series specifications
MC MultiCargo
(Multistage horizontal
centrifugal pump) design
Flow rate at optimal
efficeny Q [m
3
/h]
in
Number of impellers
Main voltage
DM 3 ~ 230/400 V
EM 1 ~ 230 V
Manufacturer's key
Pump unit
Dimensions
L2
L3
1~
3~
mm
94
94
157,5
88
88
181,5
88
88
157,5
104
88
181,5
MC 3 05 - EM / XX
D3
D1
D2
1~
R1
R1
PG 13,5
R1
R1
PG 13,5
R1
R1
PG 13,5
R1
R1
PG 13,5
3~
PG 11
PG 11
PG 11
PG 13,5