cording to the manufacturer's instructions). Pour the liquid carefully into
the water tray (5) by holding the cup directly over the water tray (see page
5). Do not pour the liquid into the water tray from high above the tray! Be
sure that no liquid enters the air outlet opening (18). This will damage the
appliance and will void any claim to the warranty.
• Let the descaling agent allow to take effect according to manufacturer's
instructions (approx. 30 min.). Check in the water tray (5) if the limescale
on the ultrasonic membrane (12) has dissolved.
• If limescale residue remains, the ultrasonic membrane (12) can be cleaned
with the help of the cleaning brush (17) (front- and backside). Do not try to
scrape them with a hard object.
• For stubborn limescale, we recommend descaling the appliance several
times in a row.
• Important: Pour the descaling agent out over the left front corner of the
appliance (see the arrow on the appliance). No water may enter the air
outlet opening (18). This will damage the appliance and will void any claim
to the warranty.
• To rinse, now fill the cup with 200 ml of tap water and carefully pour the
liquid into the water tray (5) by holding the cup directly over the water tray
(see page 5). Do not pour the liquid into the water tray from high above the
tray! Pour the water out over the left front corner of the appliance. Repeat
the process until there is no more descaling agent in the water tray (5).
Place the Water Cube (16), mist chamber (15), water tank (2) and fragrance
container (13) back into the appliance. If the water tank is not sitting right,
check if the upper part of the mist chamber (15) is properly mounted.
• Clean the water tank (2) thoroughly every two weeks with a soft brush or
sponge and warm water. Use diluted descaling agent (mix according to
the manufacturer's instructions) for lime deposits. Rinse the water tank
afterwards with clean, cold tap water thoroughly.
Replacement of the anticalc cartridge
• Please find the recommended replacement interval in the table (see «Be-
fore setup»).
• Tip: the efficiency of the cartridge (4) can be inspected with a simple test.
Hold a small mirror in the mist (19) for a few seconds. If white deposits (cal-
cium carbonate) appear on the mirror, then the cartridge needs changing.
• The anticalc cartridge is located on the inner side of the tank lid (3). First,
screw the tank lid (3) off the water tank (2) and then screw the cartridge
off the tank lid. Dispose of the cartridge in the domestic waste (4). Prior to
screwing the new anticalc cartridge into the inside of the tank lid, soak it
in water (not in the water tank!) for 24 hours.
• Keep the tank lid (3) when replacing the cartridge!
Water Cube ™
Attention: Remove water cube from plastic bag before use.
The water cube (16) keeps the humidifier fresh using activated carbon and
therefore ensures an optimal performance of the humidifier. Activated car-
bons's range of application for example includes the use in water purifica-
tion to remove pollutants, reduce heavy metals and odor-causing chemicals.
The water cube starts working as soon as it comes into contact with water,
and also works when the unit is switched off. The lifetime of the water cube