Install Heat Shield and Convection Baffle
1. Place heat shield into ZC box through the notched
cut-outs on each side at the top of box.
2. Place the tabs at the rear edge of the heat shield
into the slots. Secure the heat shield using 2 screws
on each side. Screw from within the ZC box.
3. Slide the convection baffle supplied with the heater
into the slots at the top and tighten the wingnuts.
4. Finish the installation of bricks,
logs, remote control, glass, etc. as
per instructions packed with the
RF24B heater.