Approved for use only with Valor Retrofire Model RF24BN/P Insert
Please read this manual in conjunction with the RF24B heater Installation Manual
General Application
The RA24ZC Zero Clearance Kit with RF24B heater
may be installed in new wood frame construction with
type "B" venting.
The Zero Clearance Kit is also intended for applications
where an existing gas or wood burning fireplace is
being removed in whole or in part, without disturbing
the surrounding wall finish.
•
The zero clearance box may be roughed-in on its
own and the RF24B heater installed later.
•
The minimum cavity for installing the Zero
Clearance Kit is shown in the Framing Dimensions
diagram next page. Existing type "B" gas venting
may be utilized provided the integrity is intact.
•
Existing mantel clearances must conform to the
chart.
•
For visual reasons, the zero
clearance box is painted
black on the inside; it is
recommended to paint the
vent liner and gas line with
high heat paint after installing.
4000876-04
©2010, Miles Industries Ltd.
RA24ZC
ZERO CLEARANCE KIT
Installation Instructions
Kit Content
Overview