Digital multi-display
The flash / modelling lamp power is displayed in f-stop compatible formats from 1.0 – 5.0 for
D-Lite RX ONE . The flash power difference from (e.g.) 4.0 – 5.0 is 1f-stop.
The power range is 5 f-stops, variable in 1/10th intervals. During charging or discharging, the
display «flashes». In case of overheating or malfunction, the display shows "E" for error followed
by the error code number.
Display
Joules / Ws
Note: The «D-Lite RX ONE» units have an integrated discharge system, protected by a thermal
switch. To avoid overheating, discharge manually with the «test» button if you want to
decrease the power for more than 2f-stops.
Sychronisation socket
Standard socket with 3.5 mm mini-jack (5).
N.B. Do not link ELINCHROM units by cable to other manufacturers sync. outlets.
ELINCHROM uses low voltage (5 V) for security reasons.
Open flash «test»
Having pressed the touch pad to release a flash, the green «READY» light
will appear again once the unit is recharged. If the green light does not
appear the charge system could be defective.
Please contact an authorized Elinchrom service centre.
Eye-Cell – advanced photocell sensor
The standard photocell can be remotely triggered by another flash unit!
The D-Lite RX ONE photocell is specially designed to work in studio light conditions
Direct light or other strong light sources may reduce the sensitivity of the cell.
10
1.0
2.0
6.25
12.5
3.0
4.0
25
50
5.0
100
Test and Ready (4)