3. PRODUCT OVERVIEW
3.2 TECHNICAL SPECIFICATIONS
Serial number format Home Advanced
Maximum charge capacity
Standard configured charge capacity
Electric safety category
Dimensions (H x W x D)
Weight
Standard colours
IEC-62262 IK code (robustness)
IEC-60529 IP code (protection class)
Certificates
kWh measurement
User interface
Identification
Communication backoffice
Communication Smart Meter
CONTINUED ON NEXT PAGE
INSTRUCTION MANUAL – P7
07 _ _ _ _ _ _
1-phase 32A (7,4 kW)*
3-phase 32A (22 kW)*
1-phase 16A (3,7kW)**
3-phase 16A (11kW)**
Class 1
503.5 x 200 x 137 mm
± 4.0 kg
Rear side RAL 7031 (grey)
Front side RAL 9010 (white)
IK10
IP54 (for indoor and outdoor use)
IEC-61851-1
IEC-61851-22
EV-Ready & ZE-Ready
IEC-62262 -> IK10
IEC-60529 -> IP54
MID certified
LED
RFID (NFC) Mifare 13.56 MHz
IEC 14443A
IEC 14443B
Plug & charge (through online portal)
GPRS 2G (minimal -80dBm Vodafone Partners)
Ethernet connection (DHCP, TCP 443, TCP80, TCP21)
GPRS 2/3/4G with mobile router***
RJ11 cross wired - DSMR >4.0
0130NM02INT02