3. Placement & storage conditions
The UPS has been designed to operate in a protected environment, at temperatures
between 0°C and 40°C and at a humidity level ranging between 0% and 90% (no
condensation).
Do not obstruct the ventilation slots. Install the unit in an environment which is free from
dust, chemical vapours and conductors. Moreover, in order to avoid any interference, keep
the UPS at least 20cm away from the CPU (central processing unit).
4. Connection
Check the identification plate at the back of the UPS to make sure that the power supply is
compatible with network voltage and that the device is powerful enough to protect the given
load. Plug the UPS into a 2-pole, earthed outlet (use the original power cable of your
computer or it is recommended to use a 2P+E/CEE22/10A power cable. Then, use IEC
cables to connect computer-related devices to the back of the UPS.
5. On/Off
To turn the UPS unit on, lightly press the power switch. To turn it off, press the power switch
again. Make sure that the power switch is kept in the "ON" position, otherwise the UPS will
be disabled and your equipment unprotected in the event of power failure.
Note: For maintenance purposes, please turn the UPS on before the PC and other loads,
and turn it off after the connected loads are turned off.
6. DC Start
X3 units are equipped with an integrated DC start function. To start the UPS in the absence
of a power supply and with a full battery, simply press the button.
7. Power Saving Function
X3 range is equipped with a Power Saving Function. If no load connects to the UPS, it will
automatically shut down after 5 minutes to save energy during a power failure. The Power
switch must be kept in the 'ON' position, otherwise the UPS will be disabled and your
equipment will not be protected during a power failure.
8. Connect Modem/Phone/Network for surge protection
Connect a single modem/phone line to a surge protected "IN" outlet on the back panel of the
UPS unit. Connect the "OUT" outlet to the computer with another phone line cable.
Caution: The telephone line lightning arrester could be rendered inoperable if improperly
installed. This surge protection device is for indoor use only. Never install telephone wiring
during a lightning storm.
Note: This connection is optional.
8 . C O M P U T E R I N T E R F A C E
To prevent an abrupt computer system shutdown, connect a USB cable to your computer.
Then you can install and use the automatic shutdown software (Free download from web
site).
The USB communication port at the back of the UPS enables the computer to directly
control UPS status.
The main functions are as follows:
- Transmission of a visual alarm in event of power failure
- Automatic file closure prior to the battery going flat
- Computer & UPS shutdown