Operation cont.
DC Current Measurements
WARNING:
Observe all safety precautions when
working on live circuits. Do not measure current on circuits
that exceed 600V. Measurements in the 10A range should
be limited to 30 seconds maximum every 15 minutes.
1. Set the rotary function switch to
the 10A position.
2. Insert the black test lead into the
COM input jack and the red test
lead into the 10A input jack.
3. Remove power from the circuit
under test, then open up the
circuit at the point where you
wish to measure current.
4. Touch the test lead probes in
series with the circuit being
measured. Touch the red probe
to the positive side of the circuit
and touch the black probe to the
negative side of the circuit.
5. Apply power to the circuit.
6. Read the current on the LCD display.
n m VA F M k
0
10
20
30
40
AUTO HOLD MAX MIN REL LOZ
n m VA F M k
0
10
20
AUTO HOLD MAX MIN REL LOZ
+
11
Operation cont.
Frequency and % Duty Cycle Measurements
WARNING:
when working on live voltages.
1. Set the rotary function switch to
the HZ % position.
2. Press the MODE button to select
30
40
frequency or % duty cycle. The
"Hz" or "%" symbol will appear
on the LCD display.
3. Insert the black test lead into the
COM input jack and the red test
lead into the V input jack.
4. Touch the test lead probes to the
circuit under test.
5. Read the frequency or % duty cycle
on the LCD display.
Resistance Measurements
WARNING:
-
1. Set the rotary function switch to
the
position.
2. Press the MODE button until the
" " symbol appears on the LCD
display.
3. Insert the black test lead into the
COM input jack and the red test
lead into the
4. Touch the test lead probes to the component under
test. If the component is installed in a circuit, it is
best to disconnect one side before testing to eliminate
interference with other devices.
5. Read the resistance in on the LCD display
n m VA F M k
0
10
20
AUTO HOLD MAX MIN REL LOZ
Observe all safety precautions
n m VA F M k
0
10
20
AUTO HOLD MAX MIN REL LOZ
Never test resistance on a live circuit
input jack.
12
30
40
n m VA F M k
0
10
20
30
40
AUTO HOLD MAX MIN REL LOZ
Hz
30
40
n m VA F M k
0
10
20
30
40
AUTO HOLD MAX MIN REL LOZ