12.10. CLEANING OF THE TemoCOOKING COLLECTION CASING through the oven
The smokes collection casing can be cleaned either through the oven
It will be necessary to carefully clean the exchange surfaces removing the movable part of the hob and scraping the exchange surfaces of
the furnace and the pipes which compose the tube bundle located above the oven, as well as the downward passage of the smoke on the
right side of the oven. Later clean the smoke passage under the oven. Cleaning can be made with a brush and a vacuum cleaner.
IMPORTANT: please verify that the deflectors are set as indicated in the
Pay ATTENTION that after cleaning all dismounted parts are reinstalled hermetically.
12.11. LATERAL HANDRAIL
The handles, the handrail and the tank water (cookers) should be cleaned to cold with a soft cloth and alcohol . DO NOT use abrasives
or solvents.
12.12. CLEANING OF THE HEARTH GRATE
IMPORTANT: if for whatever reason the grill is removed from the furnace, take care to reassemble it with the wider part of the slit facing
downwards (See
Picture 9 at page
12.13. MAINTENANCE ON THE WATER SYSTEM
Excessive incrustation deposits on the inner walls of the hearth considerably reduce the efficiency of heat exchange; therefore, remove
these deposits using a steel brush whenever necessary. Never use corrosive substances that can damage the thermo-fireplace and
the boiler.
With the system switched off, once a year carry out the following checks:
•
Check the operation and efficiency of the blowdown and safety valves. If they are defective, contact your authorised installer. IT IS
STRICTLY FORBIDDEN TO REMOVE OR TAMPER WITH THE SAFETY DEVICES.
•
Check the thermal insulation of the filling pipe and the safety pipe.
•
Make sure that the system is filled and under pressure, checking the water level in the expansion tank; also check that it is working
properly and check the efficiency of the safety pipe.
13. CALCULATION OF THE THERMAL POWER
There is not an absolute rule for calculating the correct necessary power. This power is given according to the space to be heated, but it
depends also largely on the insulation. On an average, the calorific value necessary for a properly insulated room is 30 kcal/h per m
an external temperature of 0°C).
Given that 1 kW corresponds to 860 kcal/h, it is possible to adopt a value of 38 W/m
Let's suppose one wishes to heat a room of 150 m
x 38 W/m
= 5700 W or 5,7 kW. As main heating, a 8 kW device is therefore sufficient.
3
Fuel
Dry wood (15% humidity)
Wet wood (50% humidity)
Wood briquettes
Brown coal briquettes
Normal anthracite
Coke
Natural gas
Naphtha
Electricity
28
60). This is to a0id furnace cleaning.
(10 x 6 x 2.5 m) in an insulated apartment. In this case, it is necessary to have 150 m
3
Approximate combustion value
Unit
kcal/h
kg
3600
kg
1850
kg
4000
kg
4800
kg
7700
kg
6780
m
7800
3
L
8500
kW/h
860
(Picture 10 at page
60) the cooker or from the top.
Picture 10 at page
60.
.
3
Required quantity in relation to 1 kg of dry
kW
4.2
2.2
5.0
5.6
8.9
7.9
9.1
9.9
1.0
TERMOREGINA 631 - DSA
3
wood
1,00
1,95
0,84
0,75
0,47
0,53
0,46
0,42
4,19
7597500 - IT - EN - DE - FR
(for
3