To ensure that the grill operates properly, it is recommended
that the island have ventilation on all 4 sides as shown in the
following illustration. The ventilation holes should be as
diagramed to ensure adequate ventilation for your grill and
island.
2
2
20 in.
(129.0 cm
) min.
ventilation both sides
1½" (3.0 cm) max.
2
2
10 in.
(64.5 cm
) min.
ventilation both sides
Proper ventilation is a required based on the above
mentioned specifications for your grill to operate properly.
LP Gas
LP Gas Pressure Regulator/Hose Assembly Location
Measurements shown are for attaching the LP gas pressure
regulator/hose assembly to the enclosure.
1¹⁹⁄₃₂" (4.0 cm)
¹³⁄₁₆" (2.0 cm)
8
5" (12.7 cm) max.
2½" (6.0 cm) max.
10¹⁄₈" (25.7 cm)
16⁷⁄₈" (42.9 cm)
Natural Gas Conversion
Natural Gas Pressure Regulator Location
Measurements shown are for attaching the Natural gas pressure
regulator to the enclosure.
2¹⁵⁄₁₆" (7.5 cm)

Gas Supply Requirements

WARNING
Explosion Hazard
Use a new CSA International approved "outdoor"
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 11" (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149.1 - latest
edition.
IMPORTANT: Grill must be connected to a regulated gas supply.
9³⁄₈" (23.8 cm)
18⁷⁄₈" (48.0 cm)
1⁹⁄₁₆" (4.0 cm)