- Unscrew the hexagon-head of the valve (A)
- Carefully clean both the rubber disk (B) and its seat.
- Refit all parts accurately.
Air losses
These can be caused by poor tightness of a union – check all
unions, wetting them with soapy water.
Compressor turns but does not load
This may be due to the breakage of the valves or of the gasket.
Replace the damaged part.
Compressor no starting
If the compressor has trouble starting, check the following:
- Does mains power match that of the data-plate?
- Are power cable extensions of adequate diameter or length?
- Is the work environment too cold? (under 0°C)
- Is there oil in the housing to ensure lubrication?
- Is power supplied to the electrical line?
Compressor not stopping
- If the compressor does not stop when maximum pressure is
reached, the tank safety valve comes into operation. To repair the
valve, contact your nearest service centre.
IMPORTANT
- Do not on any account unscrew any connection while the tank is
pressurised – always check if the tank is pressure free,
- Do not drill holes, weld or purposely deform the compressed air
tank,
- Do not do any jobs on the compressor unless you have
disconnected the power plug,
- Temperature in operating ambient: 0°C +35°C,
- Do not aim jets of water or inflammable liquids on the
compressor,
- Do not place inflammable objects near the compressor,
- During down-times, turn the pressure switch to position "0"
(OFF),
- Never aim the air jet at people or animals,
- Do not transport the compressor while the tank is pressurised,
- Be careful with regard to some parts of the compressor such as
the head and delivery tubes, as they can reach high temperatures.
Do not touch these parts to avoid burns.
- Transport the compressor, lifting or pulling it with the appropriate
grips or handles.
- Keep children and animals well away from the machine
operating area.
- If using the compressor for painting:
a) Do not work in closed environments or near to naked flames
b) Make sure there is adequate exchange of air at the place of
work
c) Protect your nose and mouth with an appropriate mask.
- If the electrical cable or plug is damaged, do not use the
compressor and contact an authorised service centre to replace
the faulty element with an original spare part.
- If the compressor is located on a shelf or on a top above floor
height, it must be secured to prevent it falling while in operation.
- Do not put objects or your hands inside the protective grilles to
avoid injury to yourself or damaging the compressor.
- Do not use the compressor as a blunt object toward things or
animals, to avoid serious damage.
- When you have finished using the compressor, always remove
the plug from the power socket.
For
the
European
market,
manufactured to meet Directive CE,(2009/105/CE)
Sound pressure level
97 dB LwA guaranteed
86.5 dB LpA
The level of acoustic pressure can increase from 1 to 10 dB(A)
according to the place in which the compressor is installed.
HINTS FOR EFFICIENT OPERATION
- For efficient operation of the machine at full continuing load and
at maximum operating pressure, make sure the temperature of
the work environment indoors does not exceed +35°C,
11
the
compressor
tanks
are
- We advise you to use the compressor at 70% maximum duty per
hour at full load as this ensures efficient operation of the product
long-term.
STORING THE PACKED AND UNPACKED COMPRESSOR
For the whole time that the compressor is not used before
unpacking it, store it in a dry place at a temperature between +0°C
and + 35°C and sheltered away from weather.
For the whole time that the compressor is not used after
unpacking it, while waiting to start it up or due to production
stoppages, place sheets over it to protect it from dust, which may
settle on the components. The oil is to be replaced and the
operational efficiency of the compressor is to be checked if it is not
used for long periods.
PNEUMATIC CONNECTIONS
Make sure you always use pneumatic tubes for compressed air
with maximum pressure characteristics that are adequate for the
compressor.
Do not attempt to repair tubes if faulty.
WE RESERVE THE RIGHT TO MAKE ANY MODIFICATIONS
WITHOUT PRIOR NOTICE WHENEVER NECESSARY