1. SAFETY WARNING

The minimum distance between the hob surface on which the pans stand
and the lower part of the hood must be 65 cm, unless otherwise specifi ed
in the installation instructions. If the hob installation instructions specify a
greater distance, it must be taken into account.
The air collected must not be conveyed into a duct used to blow off
smokes from appliances fed with an energy other than electricity (central
heating systems, thermosiphons, water-heaters, etc.).
Comply with the offi cial instructions provided by the competent authorities
in merit when installing the disposal duct. In addition, exhaust air should
not be discharged into a wall cavity, unless the cavity is designed for that
purpose.
The room must be well aerated in case a hood and some other heat
equipment fed with an energy other than electricity (gas, oil, coal heaters,
etc) operate at the same time.
In fact the intake hood, disposing of air, could create a vacuum in the room.
The vacuum should not exceed 0,04mbar. This prevents the gas exhausted
by the heat source from being intaken again. It is therefore advisable to
ensure the room contains air taps able to ensure a steady fl ow of fresh air.
Check the data label inside the appliance; if the symbol ( ) is printed, read
the following: this appliance has such technical particulars that it belongs
to class II insulation, therefore it must not be earthed.
Check the data label inside the appliance; if the symbol ( ) is NOT prin-
ted, read the following:
When making the electrical connections, check that the current socket has
a ground connection.
When making the electrical connections, check that the voltage values
correspond to those indicated on the data plate inside the appliance itself.
In case your appliance is not fi tted with a supply cord and a plug or with
other means for disconnection from the supply mains having a contact
separation in all poles that provide full disconnection under overvoltage
category III conditions, that means for disconnection must be incorporated
in the fi xed wiring in accordance with the wiring rules. If your unit features
a power lead and plug, position this so the plug is accessible.
Always switch off the electricity supply before carrying out any cleaning
or servicing operations on the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualifi ed persons in order to avoid a hazard.
ATTENTION: This appliance must be earthed.