PROGRAMMING INSTRUCTIONS

1.
There are 4 red LED lights, each one representing a different level of water
hardness. One red LED light is for the softest water, four red LED lights is for
the hardest water.
2.
To set the programme, hold the button "R" (Diagram B – #6) button down
while at the same time turning the boiler on/off switch (Diagram C – #5) on.
3.
The green LED (5) will start to flash.
4.
"Push" and "release" the "R" button until you have the correct number of
red LED lights lit as per the litmus paper test. Hold the "R" button down for
5 seconds until you hear an audible "beep." Once you hear the beep, the
programme is set.
5.
To verify the setting you have made, you can repeat steps #2 – #3 and you
will see the number of red LED lights lit up as per your selection (including
the flashing green light). Release the "R" button and after 15 seconds the
lights will automatically go off.
ANTI-CALC WARNING ALARM
If you hear a beeping sound from the boiler, and at the same time all the red LED
lights are flashing (after 1 minute they will stop flashing and stay on), this means
that it is time to proceed with the de-scaling of the boiler tank.
ATTENTION:
It will be still possible to work for a short time while the boiler is
in the alarm mode, after which the steam station will auto-protect itself from the
scale and stop working until you de-scale the boiler.
SPECIAL NOTE
The J490A anti-calc warning system will automatically shut itself off after 57 gal-
lons (218 litres) of water, if the programming instructions have not been followed.
It is suggested that you first clean the boiler following the cleaning instructions
outlined on page 10. Then programme the anti-calc system following the instruc-
tions above (#2 – #5) to reset the programmer.
RESET THE PROGRAMME
Once you have de-scaled the boiler (see section Maintenance of the Boiler) you
have to proceed with the RESET before starting to iron again. Repeat step #2
(in the programme instructions above and hold the "R" button down for 10 seconds.
When you hear the beap, the programme is reset.