Maytag MGD6000XW Guide D'utilisation Et D'entretien page 17

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

First try the solutions suggested here or visit our website at www.maytag.com/help
if you experience
dryer results (cont.)
Odors
Load too hot
dryer displaying Code Message
"PF" (power failure)
"L2" Diagnostic Code
(low or no line voltage
condition)
"AF" (low airflow
condition)
"F# E#" (F1 E1, F3 E1, etc.)
variable service codes.
for assistance and to possibly avoid a service call.
Possible Causes
Recent painting, staining, or
varnishing in the area where your
dryer is located.
For steam cycles, the water is not
properly connected with the dryer.
Odors are left in garments after
wearing.
Load removed before cooldown
portion of cycle complete.
Using Timed Dry cycle with a high
temperature setting.
The drying cycle has been
interrupted by a power failure.
There may be a problem with your
home power supply keeping the
dryer's heater from turning on.
The lint screen or vent is clogged;
the vent is crushed or kinked or
has too many turns.
The dryer is in need of service.
Ventilate the area. When the odors or fumes are gone from
the area, rewash and dry the clothing.
Make sure water is connected to the dryer. Check that water
inlet hose is connected to both the faucet and dryer's water
inlet valve. Check that the water supply is turned on.
To remove odors left in garments after wearing, select Auto
Refresh. This cycle is best for reducing wrinkles and odors
from loads consisting of wrinkle-free cotton, cotton polyester
blends, common knits, and synthetics.
Allow the dryer to complete the cooldown portion of the cycle
before removing the load.
Select a Sensor cycle with a lower heat setting to avoid
overdrying the load.
Press and hold START to restart the dryer.
The dryer will continue to run when this diagnostic code is
present. Press any key to clear the code from the display and
return to the estimated time remaining.
Try the following:
Check to see if a household fuse has blown or circuit breaker
has tripped. Electric dryers use two household fuses or
breakers. Replace the fuse or reset the circuit breaker.
Confirm the power cord is properly installed. Refer to
"Installation Instructions" for details.
Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, consult a qualified electrician.
The dryer will continue to run when this diagnostic code is
present. Press any key to clear the code from the display and
return to the estimated time remaining.
Try the following:
• Clean lint screen.
• Check to see if the vent run from the dryer to the wall is
crushed or kinked.
• Confirm the vent run from the dryer to the wall is free of lint
and debris.
Confirm the exterior vent exhaust hood is free of lint and debris.
Confirm your vent system falls within the recommended run
length and number of elbows for the type of vent you are using.
Refer to "Plan Vent System" in the Installaton Instructions for
details.
Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, have your entire home venting run
cleaned.
If a code beginning with an "F" appears in the display.
Alternating between F# and E#, the dryer control has
detected a problem that requires service. Call for service.
Solution