Ce Declaration Of Conformity - Facom V.CA50F Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
PLACING THE MACHINE IN SERVICE
LUBRIFICATION
Always use of an air line lubricator with these machine. We recommended the
following Filter-Lubricator-Regulator Unit: FACOM N.580.
Every eight hours' operation, if a lubricator is not used on the compressed air
network, inject 1/2 to 1cm
through the machine's inlet connection.
3
NEVER USE THE ANGLE CUT-OFF TOOL WITHOUT THE SAFETY GUARD
Model
Deburring
Motor power
wheel
rating
mm
V.CA50F
Ø 50
Model
Rated speed
rpm
V.CA50F
20000
* k = measurement uncertainty in dB ** k = measurement uncertainty in m/s²
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - 91 420 MORANGIS - FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE PRODUCT V.CA50F
– FACOM Ø 50 MM ANGLE CUT OFF TOOL
- IS IN CONFORMITY WITH THE «MACHINERY» DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD EN ISO 11148-7: 2012
The undersigned is responsible for compilation of the technical fi le and makes this declaration on behalf of Facom.
NU-V.CA50F_0616.indd 8
Center hole
max. wheel
diameter
wide
kW
mm
mm
0,3
max. 10
max. 3
Air
Working
consumption
pressure
l/min
bar
113
6,2

CE DECLARATION OF CONFORMITY

EMERGENCY
GATE VALVE
?
10 mm
Ø 22,23 mm
Noise level
Pressure dB(A)
Power dB(A)
k*
81
3
92
Weight
Dimensions
kg
mm
0,54
138 x 59 x 85
Vibrations level
m/s
Pressure dB(C)
k*
k*
3
130
3
1,7
Markus Rompel
20.03.2016
Director Engineering
17/06/2016 13:31:23
2
k**
1,02

Publicité

Table des Matières
loading

Table des Matières