The blower unit includes the following :
- a box
- a fan support with a 230 V 50 Hz 30 W
motor fan
- a fan shield
- a selector with two speeds and stop
- a thermostat which sets in motion the
ventilator in accordance with the fireplace's
temperature, if the selector
or II.
- a selector AUTO/MANU
- UTILIZATION
Select a speed of ventilation :
. Little speed, selector in position I
. High speed, selector in position II
Put in heating the apparatus (see § 5.5).
For the versions with thermostat, select automatic
operation (AUTO) or manual operation (MANU)
with the selector :
- In the MANU position : the fan is switched on
and off by manual control. In this position, the
blower function can be started up immediately
and must be switched off by hand.
- In the AUTO position : the fan is operated
automatically, when the whole of the apparatus
is warm, generally during the following hour the
lighting. Its running is interrupted when the
apparatus is cold, generally at the fireplace's
extinction.
If you want the blower to be started up immediately
and then switched off automatically, select the MANU
position when lighting and then switch to the AUTO
position once the appliance is hot. The blower will
then be switched off automatically.
5.5.2.3 - Ash removal
•
The air used for the wood combustion goes under
the grid when the air knob control is open. This
air is also used to cool the grate. To ensure
optimum performance and to avoid damaging the
grate due to overheating, it is very important that
it not be obstructed. The grate should therefore
be cleaned regularly and the ashes removed.
Extracting the ash box.
•
Unlock the ash pan door. Position the end of the
poker in the hole on the ash pan door handle and
move the poker as shown in Fig. 18.
•
The scraper may be used to remove ash from the
grate (Fig. 17).
•
The ash pan, located under the grate, is easily
removed by pulling it out with the poker.
•
Remove periodically any ash which spilled
accidentally in the ash box compartment.
The level of ashes must never reach the cast
iron grate : de-ash every 2 to 3 days.
www.pieces-de-poele.com
5.5.2.4 - Safety rules
•
•
•
is in position I
•
•
•
•
6
INSTRUCTIONS
6.1 - Maintenance and sweeping of the chimney
•
•
18
Never dowse the fire with water to put it out.
The front glass as well as other parts of the stove
are very hot : be aware of the risk of burns,
particularly when small children are present.
The fireplace radiates a significant amount of
heat even through the glass : do not place heat-
sensitive materials or objects at a distance closer
than 1.50m from the glass.
Empty the ash pan into a metal or nonflammable
container intended for this purpose. Although the
ashes may appear to be cold, they may still be
very hot even after a long cooling-down period.
Do not place easily inflammable materials near
the fireplace or in the woodbox.
Cautious, do not store the firewood under the
appliance (Fig. 19).
In case of fire in the hearth, turn the thermostat
on position 0 and close the ventilation duct.
-
MAINTENANCE
flue
The chimney flue must be mechanically swept.
This operation should be performed several times
per year and at least once during the heating
season. A certificate should be handed in by a
qualified professional.
Prior to sweeping operations :
Set down the deflector, the fireback, and the
-
joining up pipe.
Proceed with the dismantling of the deflector :
-
Have the deflector got through P guide
pins (Fig. 22) and have it out off
slantwise (Fig. 23).
Dismantling of the ventilation shaft :
after having dismantled the deflector
(Fig.20, 21 and 22 ) loosen the ( A )
screw ( box spanner H 10 ), partially
free the lever and its operating lever
stem, without getting them out off the
grate, in order to free the shutter (Fig.
24).
NOTA BENE : Have the lever on
vertical position to have the spin
getting through the grate easily.
Reassembly of the ventilation shaft :
for the reassembly act the other way
round
(vertical
vertical shutter) and that the shutter
horizontally positioned (circular rib
must be in contact with the horizontal
part inside the appliance) to ensure
the water tightness.
AND
SWEEPING
box
spanner
for