5.1 Electrical Connection

supply corresponds to the supply value indicate on the label affixed to the machine. -
Mains connection must conform to applicable standards, with a properly functioning
earth (ground) connection. Call in a skilled electrician to fit a high sensitivity differential
switch with a 30 mA or lower tripping threshold. - In case of need, it is possible to use
feeding cable extension with wire section of 1,5 mm
mm
for lenght between 10 and 30 mt. If the original power supply cable must be
2
replaced, use a new cable having a suitable crosssection with an earth (ground) lead;
the cable must have a continuous insulating sheath suitable for use both outside and
inside; combustion product discharge must take place in conformity with applicable
standards.
5.2 Connection To The Stack
INDIRECT models require a fume discharge system. A stack must be installed (flexible tubing
is allowed) with a minimum diameter of 120 - 150 mm.
DIRECT models should be used exclusively in well aired environments.
6.
START - STOP
6.1 Start (without environment thermostat)
-Fill the tank with fuel.
-Insert the plug in the mains socket (the red LED comes ON).
-Place the ignition switch to ON (the green LED comes ON and the fan begins operating).
The automatic ignition cycle commences, through the control equipment.
After a few seconds of automatic monitoring, the generator begins operating normally. If the
unit comes to a halt because of minor functional irregularities and the RESET PUSH-BUTTON
LED comes ON, press this button to repeat the ignition cycle.
6.2
Stop (without environment thermostat)
-Place the main switch to OFF.
-Combustion halts while the fan continues to cool the interior of the generator. During this
stage, fan operation may be continuous or intermittent until complete cooling is achieved, as
measured by the post-cooling thermostat located onboard the boiler.
GB
Before starting the unit, make sure that the mains electricity
Please, connect the chimney using the union kit ( see picture )
for lenghts up to 10 mt. and 2,5
2
4
Chimney
Union kit
Flue gas exhaust
chimney hood