For multiple amplifi er installations where distribution blocks are used, each amplifi er should have its proper-rated
fuse, or breaker, installed between the amplifi er and the distribution block within eighteen inches of the block,
or on the distribution block if it provides for fusing. The primary power wire should also be fused between the
battery and distribution block, within eighteen inches of the battery's positive terminal, with a fuse or breaker
rated at least to the sum of the individual amplifi er's fuse values
≤7"
(18cm)
external fuse
to amplifi er
2016 DXA Mono Amps Rev D.indd 4
2016 DXA Mono Amps Rev D.indd 4
external fuse
power distribution block
≤7"
(18cm)
external fuse
to amplifi er
≤7"
(18cm)
12V
battery