RRM / RRE 500, 800, 1000, 1300, 1500, 1800
How to mount the heater
Always respect the minimum dimensions shown in the last picture on the next page.
1. After selecting the location to install the thermal emitter, place an upper support vertically on the
wall and mark the two holes with a spacing of 30 mm. Once done, and depending on its thermal
emitter, choose the distance D1 with respect to the previous signals (Fig 3)
Model
RRE 500 / RRM 500
RRE 800 / RRM 800
RRE 1000 / RRM 1000
RRE 1300 / RRM 1300
RRE 1500 / RRM 1500
RRE 1800 / RRM 1800
2. Make four holes, insert wall plugs and screw the upper brackets to the wall (Fig 4)
3. Screw the bottom to the bottom of the emitter.
4. Hang the thermal emitter and mark the point to be drilled bottom bracket (Fig 5).
5. Lift the transmitter and make the hole.
6. Hang transmitter again and screw the bottom bracket to the wall so that the sender is completely
fixed (Fig 6
wall
floor
Hang up
Lengh (D1)
155 mm
155 mm
155 mm
155 mm
542.5 mm