Problem:
No output signal at the loudspeakers;
the LEDs above the 
buttons
PROTECTION circuit has tripped).
Cause 1:
The PROTECTION circuit has tripped due
to overheating or overloading.
Remedy:
Reduce volume and wait for about
20 seconds. If the unit does not switch on
again automatically, it has become too hot
and should be left switched off for a few
minutes to cool down.
Cause 2:
Short-circuit in the speaker leads, e. g.
stray wire ends touching at the speaker
terminals, or mechanical damage to the
cables.
Remedy:
Check speaker leads and terminals, twist
wire
ends
damaged cables.
Cause 3:
Overloading due to poor earth contact.
Remedy:
Disconnect input cable and wait to see if
the amplifier switches back on again; if so,
check the input lead and replace if
necessary.
Problem:
Unit switches off repeatedly at fairly
high volume levels.
Cause 1:
Overheating due to heat build-up.
Remedy:
Set up the unit in such a way that an
unobstructed
guaranteed.
Cause 2:
Overheating
loudspeaker impedance.
Remedy:
Use only loudspeakers of at least 4 Ω
impedance (DIN rating). That means a
minimum impedance of > 3.2 Ω.
Problem:
Flat sound image, insufficient bass
response.
Cause:
The loudspeaker cables are connected
with reversed polarity.
Remedy:
Check the speaker connections at the
loudspeakers
speaker terminals; correct if necessary.
 and 
flash
alternately
together
neatly,
replace
flow
of
cooling
air
through
insufficient
and
at
the
amplifier's
(the
is
41

Publicité

loading

Produits Connexes pour T+A P 1230 R

Ce manuel est également adapté pour:

Pa1230 rPa 1530 r