Replacing Filters - NateoSante EOLIS Air Manager 600 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

replAcing FilterS

When should I replace the pre-filter?
the lifespan of the pre-filter depends on the environment in which it is used. the pre-filter should be replaced
regularly (every 3 to 4 months on average) in order to limit filter clogging. It is essential that you monitor the pre-filter
regularly to check its status.
How do I replace the pre-filter?
1 • turn off your unit.
2 • Open the front cover and remove the filters using the 2 tabs designed for this purpose.
3 • Remove the used pre-filter from the filters to replace it with a new one.
4 • Put the filters back in, with tabs facing out.
5 • Close the front cover. Make sure the front cover is positioned correctly, to ensure that your unit will operate
correctly.
6 • turn on the unit. the new filter is tested by the "filter test" system. "New filter?": You can say NO (only for changing
built-in filters).
When should I replace the filters?
the lifespan of the filters depends on how the unit is used and the concentration of pollutants in the air (between 10
and 12 months if the unit operates 24/7). For an instant status of your filters' conditions, see the real filter service
indicator (see page 19). It is sometimes necessary to replace the filter after it has been used for de-pollution after
construction or prolonged use in a very polluted environment (thick smoke, strong persistent odours, etc.)
Do not clean the filter, place it in water or vacuum it: this could cause changes in the fibres or cartridges, leading to
poor operation or reduced efficiency of your air manager.
If the alert icon
appears on the control screen, a message indicating the advanced use status will appear.
You will receive an alert when your filters are 80% clogged. Depending on the use level of your filters, your unit will
alert you as follows:
• 80% used filter: "Plan to change filters"
• 100% used filter: "Purifier OFF - Pending filter change"
If the filter reaches 100% saturation, the unit will stop working to prevent damage to the motor. It will start working
again as soon as you have changed the filters.
How do I replace the filters?
1 • do not tUrn oFF yoUr Unit.
2 • Open the front cover and remove the filters using the 2 tabs designed for this purpose.
3 • Remove the new filters from their packaging, making sure not to damage them.
4 • Put the filters back in, with tabs facing out.
5 • Close the front cover. Make sure the front cover is positioned correctly, to ensure that your unit will operate
correctly.
6 • the new filters are tested by the "filter test" system. "New filter?": you can say YES. If the front cover is open but
you have not changed the filters, you can say NO or ignore the message.
replAcing Uv lAmpS
When should i replace the Uv lamps?
the UV lamps will wear differently depending on how often you activate the UV LAMP (or photocatalysis) feature.
the lifespan for a UV lamp is generally 1 to 2 years.
how do i replace the Uv lamps?
1 • turn off your unit.
2 • Open the front cover and remove the filters to reach the UV lamps.
3 • to remove or replace a lamp, pull it gently and vertically upwards.
4 • Remove the new lamps from their packaging taking care not to damage them and place them in the unit where the
old lamps were.
5 • then put the filters back in, with tabs facing out.
6 • Close the front cover. Make sure the front cover is positioned correctly, to ensure that your unit will operate
correctly. Your air manager is ready to operate again.