g� List of alarms / events
Alarm 01: Probe PT100
Alarm 02: Overheating. Tem-
perature above 220°C
Alarm 03: Platen safety sys-
tem triggered
Alarm 06: Upper pressing
sensor not reached
Alarm 07: Lower pressing
sensor not reached
Alarm 08: Right rotation sen-
sor not reached
Alarm 09: Left rotation sen-
sor not reached
Alarm 10: Communication
error
Alarm 13: Temperature not
reached.
14
Press the red/orange area to clear the fault.
Probe signal lost (sensor or cable). The
heating control is instantly disabled.
Temperature reading above 230°C. The
heating control is instantly disabled.
Detection is immediate. The heating
control and pressing operation are ins-
tantly disabled.
Signal not detected after 5 seconds.
Caused by faulty sensor, lack of com-
pressed air supply, jamming (mechanical,
etc).
Signal not detected after 5 seconds.
Caused by faulty sensor, lack of com-
pressed air supply, jamming (mechanical,
etc).
Signal not detected after 5 seconds.
Caused by faulty sensor, lack of com-
pressed air supply, jamming (mechanical,
etc).
Signal not detected after 5 seconds.
Caused by faulty sensor, lack of com-
pressed air supply, jamming (mechanical,
etc).
Communication
lost
board and screen board.
Contact your stockist.
Blocks first cycle start request. Permits
cycle start at second request (forced start
despite setpoint not being reached).