3.4 Indicating the measured gas concentration (Alarm or safe)

Whether petrol vapour and/or carbon monoxide has been detected by the sensor and/
or whether the sensor is functioning properly is indicated by an acoustic alarm and two
LEDs, one for each sensor
The indication is as follows:
LED
LED
1 s - 0,25 s - 0,25 s - 1 s
0,3 s - 8 s
LED
1 s - 0,25 s - 0,25 s - 0,25 - 0,25 s - 1 s
0,3 s - 8 s
LED
1 s - 0,25 s - 0,25 s - 1 s
0,6 s - 0,3 s
LED
1 s - 0,25 s - 0,25 s - 0,25 - 0,25 s - 1 s
0,6 s - 0,3 s
LED
0,5 s - 0,5 s
0,15 s - 8 s
NB: if no sensors are connected to the gas detector it cannot function. Both LEDs
will flash RED until at least 1 sensor has been detected.
1
SENSOR
2
Gas detector PD1000
.
1
SENSOR
2
GREEN
Safe
GREEN
Warning
CO
GREEN
Warning
Petrol vapour
RED

Alarm

CO
RED
Alarm
Petrol vapour
RED
Attention
No combustible gas or CO has
been detected.
A minimum amount of CO has
been detected, but less than the
alarm level. This is in the warn-
ing range.
A minimal amount of petrol
vapour has been detected, but
less than the alarm level. This is
the warning range.
An amount of CO higher than
the alarm level has been detect-
ed.
An amount of petrol vapour
higher than the alarm level has
been detected.
The sensor is faulty or aged.
100106.01
ENGLISH
17