AQUALUX 104274 Notice D'installation Et D'utilisation page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Non-contractual scheme, pool water input / output water on back side
Dim (mm)
A
310
104274
390
104275
390
104276
500
104277
500
104278
500
104279
LIST OF ITEMS SUPPLIED
1 heat pump + 2 x 50mm diameter fittings + condensate drain
-
1 digital remote control panel + 10 m of cable
-
1 manual
-
STEPS IN THE INSTALLATION PROCESS
Position
- The heat pump must be installed OUSTSIDE in a well ventilated place, far from any sources of
combustibles. In order to reduce noise levels, position the fan (air inlet – outlet) parallel to the living
space.
The water pipe between the pool and the heat pump must not exceed 10m.
Provide for the discharge by gravity of condensates under the machine.
For maintenance reasons, the pump must not be placed in an area where vegetation is present (leaves,
pine needles, etc.).
Ideally, the heat pump should be protected against outdoor phenomena (rain, snow, etc.) by a shelter.
- The frame is secured with screws (M10) on a concrete slab type structure solid and sets capable of
supporting the weight of the heat pump and allowing the natural evacuation of rainwater and condensate.
Wood supports or other deformable, corrodible and / or hydrophobic material is prohibited. The
mounting of anti-noise systems is recommended ref 104284 (optional).
NOTPACAQX - ind Q – 0413
B
C
590
300
590
380
590
380
790
490
790
490
790
490
Heatpump
pummpe
Technical room
Pool
D
E
340
961
420
961
420
961
530
1161
530
1161
530
1161
50 cm mini
control panel
14/41
F
G
280
107
290
107
290
107
600
107
600
107
600
107
H
658
658
658
958
958
958