Troubleshooting Guide - EINHELL Expert GE-AW 9041 E Mode D'emploi D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25

10. Troubleshooting guide

Faults
Motor fails to start
up
No intake
Inadequate delivery
rate
Thermostat swit-
ches pump off
Anl_GE_AW_9041_E_SPK1.indb 21
Anl_GE_AW_9041_E_SPK1.indb 21
GB
Cause
- No mains voltage
- Pump rotor blocked -thermostat
switched off
- Non-return valve dirty
- Pump chamber without water con-
nection
- Air in intake line air-tight
- Max. suction height exceeded
- Suction height too high
- Coarse fi lter dirty
- Water level falling rapidly
- Pump performance diminishedby
contaminants part
- Motor overloaded - friction caused
by foreign substances too high
- 21 -
Remedy
- Check voltage
- Dismantle and clean pump
- clean
- Fill water into intake
- Make sure intake line is close
- Check suction height
- Check suction height
- clean
- Place the suction hose at a deeper
level
- Clean pump and replace wearing
- Dismantle and clean pump. Prevent
intake of foreign substances (fi lter)