Technical data
Type
Rated output
Rated capacity
CLICKFIX plus installation technology
Pressure stop
Drip stop
Mixed water quantities 40 °C
(15 °C/85 °C) / (15 °C/85 °C)
Variable temperature adjustment up to
Stand-by power consumption
at 65 °C/24 h
Electrical connection
Heat-up time to 60 °C
(supply temperature 12 °C)
Fuse protection
Water connection
Maximum flow
Cable length
Dimensions (Height x Width x Depth)
Weight, filled
Energy efficiency class
Load profile
Annual energy consumption
Daily energy consumption
Sound power level
Hot water heating energy efficiency
en
DO05705
DO05755K
Undersink
[kW]
2.2
[l]
5.0
[l]
9.5/14
[°C]
85
[kWh/d]
0.18
[V]
230
[min]
8
[A]
10
["]
3/8
[l/min]
5
[m]
0.6
[mm]
435 x 270 x 240 435 x 270 x 240 435 x 270 x 240 435 x 270 x 240
[kg]
7.7
A
XXS
[kWh]
477
[kWh]
2.260
[dB]
15
[%]
37.8
DO3170D5
DO05805
DO3175D5
DO05855
DO05705CH
Undersink
Over-sink
1.8
2.2
5.0
5.0
–
–
9.5/14
9.5/14
85
85
0.18
0.18
230
230
9
8
10
10
3/8
1/2
5
5
0.6
0.6
7.7
7.7
A
A
XXS
XXS
484
481
2.340
2.310
15
15
36.8
37.2
DO3185D5
DO05805CH
Over-sink
1.8
5.0
–
–
9.5/14
85
0.18
230
9
10
1/2
5
0.6
7.7
A
XXS
484
2.340
15
36.8
13