Fire Safety; In A Emergency; Technical Description - LA NORDICA CANDY Instructions Pour L'installation, L'utilisation Et L'entretien

Masquer les pouces Voir aussi pour CANDY:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

• Make sure that the floor can support the weight of the appliance (for ex. distributing weight plate), and if it is made of flammable
material, provide suitable insulation (DIMENSIONS ACCORDING TO REGIONAL REGULATIONS).
• Make sure that there is adequate ventilation in the room where the appliance is to be installed, with particular attention to windows
and doors with tight closing (seal ropes).
• Do not install the appliance in rooms containing collective ventilation ducts, hoods with or without extractor, type B gas appliances,
heat pumps, or other appliances that, operating at the same time, can put the room in depression (ref. UNI 10683 standard).
• Make sure that the flue and the pipes to which the appliance will be connected are suitable for its operation. It is NOT allowed the
connection of various appliances to the same chimney.
• The diameter of the opening for connection to the chimney must at least correspond to the diameter of the flue gas pipe. The
opening must be equipped with a wall connection for the insertion of the exhaust pipe and a rosette.
• The installation must be appropriate and has to allow the cleaning and maintenance of the product and the flue.
La NORDICA S.p.A. declines all responsibility for damage to things and/or persons caused by the system. In addition, it is not
responsible for any product modified without authorisation and even less for the use of non original spare parts.
Your regular local chimney sweep must be informed about the installation of the appliance so that he can check the correct connection to
the chimney.

4. FIRE SAFETY

When installing the product, the following safety measures must be observed:
a)
In order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or furnishing components
flammable and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and from materials with flammable structure (see
Picture 4 at page 60
be used.
b)
In front of the furnace door, in the radiation area there must be no flammable or heat-sensitive objects or material at a distance of
less than 100 cm. This distance can be reduced to 40 cm where a rear-ventilated, heat-resistant protection device is installed in
front of the whole component to protect.
If the product is installed on a non totally refractory floor, one must foresee a fireproof background. The floors made of inflammable
c)
material, such as moquette, parquet or cork etc., must be covered by a layer of no-inflammable material, for instance ceramic,
stone, glass or steel etc. (size according to regional law). The base must extend at least 50 cm at the front and at least 30 cm at
the sides, in addition to the opening of the loading door (see
d)
No flammable components (e.g. wall units) must be present above the product.
The Product must always operate exclusively with the ash drawer inserted. The solid combustion residues (ash) must be collected in a
sealed, fire resistant container. The Product must never be on in the presence of gaseous emissions or vapours (for example glue for
linoleum, petrol etc.). Never deposit flammable materials near the Product.
During combustion, thermal energy is released which leads to considerable heating of the surfaces, doors, handles, controls, glass parts,
the flue gas pipe and possibly the front part of the appliance. Avoid contact with these elements unless using suitable protective
clothing or accessories (heat resistant gloves, control devices).
Ensure children are aware of these dangers and keep them away from the furnace when it is on.
When using the wrong fuel or one which is too damp, due to deposits present in the flue, a flue fire is possible.
4.1.

IN A EMERGENCY

If there is a fire in the flue connection :
a)
Close the loading door and the ash drawer door
b)
Close the comburent air registers
c)
Use carbon dioxide ( CO
d)
Request the immediate intervention of the Fire Brigade
DO NOT PUT OUT THE FIRE WITH WATER.
When the flue stops burning, have it checked by a specialist to identify any cracks or permeable points.

5. TECHNICAL DESCRIPTION

The chimney stoves of La Nordica are suitable to heat living spaces for some periods. As fuel, wood logs are used. The appliance works
as an intermittent operating appliance.
The stove is made of raw and enamelled meltings of cast iron.
The hearth is totally sheathed with single cast-iron sheets. Its back is extractable. Thanks to calibrated holes, made on the same back, it
is guaranteed a supply of pre-heated air inside the hearth, thus obtaining a post-combustion which increases the efficiency and reduces
the emission of the unburnt gases. Inside it there is a turning and extractable grate. The inside smoke plate, reflects the fire radiation and
increases the internal temperature of the combustion chamber. This process together with the exhaust gases flows, makes optimal the
combustion and improves the efficiency (see
16
- A). All the minimum safety distances are shown on the product data plate and lower values must not
powder ) extinguishers to put out the fire
2
Picture 9 at page
Picture 4 at page 60
- B).
61).
CANDY - BRIGITTA
7199302

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Brigitta

Table des Matières