the weka product having been installed on an incorrect foundation or floor plate, etc., in particular in
-
case of violation of the rules of architecture,
lack of or insufficient care of the wood (maintenance measures such as preservation or painting of the
-
wood),
wind speeds stronger than force 7 (moderate gales), natural catastrophes or brute force having caused
-
the damage to the weka product,
the deficiency consisting in changes which are typical for wood, such as discoloration, formation of
-
cracks, warping, shrinking, swelling or similar normal effects on the material "wood".
Warranty claims must be accompanied by the original packing slip and the original sales receipt and must be
submitted within the warranty period in writing or by fax or e-mail. A further prerequisite for a claim is the
immediate notification of the defect or damage in the form of pictures and a written description of the defect.
Address all warranty claims to:
weka Holzbau GmbH, Johannesstraße 16, 17034 Neubrandenburg
Fax: 0395/42908-83; E-mail: info@weka-holzbau.com
NOTE! For retrofitting of wall elements, equipment and storage rooms, or other wall coverings, constant
and full-surface ventilation underneath the roof panels is required, as otherwise heat may be built up
and the roof panels damaged.
For this, a minimum distance of 20 cm up to the roof panels must be ensured.
NOTES – ROOF TILES
•
Prior to mounting, the roof tiles are to be stored undercover and out of direct sunlight. This applies in
particular to white foils. Heat may build up under a stack of tiles leading to distortion and discoloration of
the tiles due to the burning glass effect.
•
Roof tiles must not be mounted in temperatures below +5°C or above 30°C.
•
In order to guarantee the impermeability of your car port, silicon is to be used when laying the roof tiles (not
included in the delivery.
•
The roof tiles are to be pre-drilled with holes with a diameter = 10 mm.
•
Please note that the tiles are to be screwed into place on the front and back purlin on every 2nd wave, on
the centre purlins on every 3rd wave.
•
Use the spacers (item 23) according to the.
•
Please note that the screws are not to be screwed down too tightly in order to guarantee the function of the
tiles.
•
Note: No false floor may be installed or thermal insulation provided below the roof tiles. There must be
adequate ventilation beneath the roof tiles.
•
The maximum snow load for this carport is 1,25 kN/m², resulting in a maximum permissible snow depth of
0,60 m. If the snow depth exceeds this amount, the roof must be cleared.
TOOL
You should have the following tools to hand before beginning assembly. (Not supplied.)
Spring tape measure
Drill
Spanner
Technische Änderungen vorbehalten! Alle Maßangaben sind ca. Maße.
Spirit level
Electric screwdriver
Pencil
Taper drill
= Entrance
Copyright HRB 3662
5
Mitre saw/hand disk saw
Screw clamp