9.
MAINTENANCE
WARNING! Maintenance must be carried out by technical staff trained and enabled for intervention
on the flammable refrigerants.
WARNING! Any work carried out on the appliance by the user strictly requires the power plug being
disconnected from the mains socket.
ATTENTION! Use protective shoes and gloves during maintenance operations.
OPERATION
Cleaning the outer surface
Cleaning the accessible inner parts (do not use tools)
Checking the power supply, electrical plugs and/or sockets
Seals intactness check
Check the acceptable condition of warning plates
Fridge system tubing intactness check
Inspecting the cables and inner power connections
Replacing the power supply cable
Control panel replacement (electronic control unit)
Any other maintenance operation not planned in the previous points should be carried out by the
support centres authorised by our dealers or by qualified staff.
10. OUTER CLEANING
WARNING! TURN OFF POWER SUPPLY TO THE CABINET BY DISCONNECTING THE POWER
PLUG BEFORE CLEANING.
For a good preservation of the cabinet's body a periodical cleaning is necessary.
1. EXTERNAL BODY
: When necessary, the external body should be cleaned with a cloth and a neutral soap and water solution.
2. SURFACES IN PLASTIC MATERIAL
under no circumstances should alcohol, methylated spirits or solvents be used.
3. TOUCH SCREEN
: Never use solvents of any kind, never pour water directly on the screen. Slightly dampen a cotton
cloth and pass it over the screen to remove dirt or foreign bodies. Dry the screen well and pass over it with a microfibre cloth.
11. TANK CLEANING
WARNING! TURN OFF POWER SUPPLY TO THE CABINET BY DISCONNECTING THE POWER
PLUG BEFORE CLEANING.
By tank cleaning, proceed as follows:
1.
Remove the product from inside the tank.
2.
Unplug the unit.
3.
Leave the doors open and begin the operation of tank washing when the tank temperature is the same as the ambient
temperature.
4.
Wash inside the tank carefully with neutral soap, without using large quantities of water.
5.
Rinse and AMBIENT carefully.
6.
Re-start the equipment and wait for it to reach temperature before filling it again.
Do not use any aggressive or abrasive cleaning agents.
Never use a water hose or a high-pressure jet to clean the cabinet.
WARNING! Do not use jet of water to clean the cabinet: electrical wiring could be damaged.
WARNING! Never use mechanical devices or any other means to accelerate the defrosting process,
other than those recommended by the manufacturer.
12. FINNED CONDENSER CLEANING
At least once every 30 days proceed with cleaning of impurities from the finned capacitor (dust and
dirt) that accumulates between the fins on the front surface, obstructing good air circulation.
A dirty condenser reduces the performance of the equipment, increasing the energy consumption.
Cleaning should be carried out with a soft brush or preferably with a vacuum cleaner.
Operation must be carried out by qualified technical staff.
EPTABRIKS OUTDOOR
EPTA S.p.A. - Sede legale
Via Mecenate, 86 - 20138 Milano – Italy
Capitale € 68.515.000 - R.E.A./MI – 1730229
Registro delle Imprese e Cod.Fiscale n. 04160730968
Partita IVA 04160730968
FREQUENCY
Based on use
Based on use
: Wash with warm water and mild detergent, rinse well and dry with soft cloth;
MAINTENANCE
Ordinary
Ordinary
Six-monthly
Ordinary
Six-monthly
Ordinary
Six-monthly
Ordinary
Six-monthly
Ordinary
Six-monthly
Ordinary
-
Extraordinary
-
Extraordinary
2 2 / 7 2
PAGE
UM000417
N° DOC
AUTHORISED STAFF
User
User
User
User
User
Technical support
Technical support
Technical support
Technical support